Contatores auxiliares 3TH20, 3TH3
Contatores auxiliares 3TH42
Blocos aditivos para 3TH3
2NA + 2NF
14
A1
A2
13
22
21
44
43
32
31
3TH20 223TH30 22
3NA + 1NF
14
A1
A2
13
22
21
44
43
34
33
3TH20 313TH30 31
4NA14
A1
A2
13
24
23
44
43
34
33
3TH20 403TH30 40
1NA(com indicador de estado ligado-desligado)
3
4
3TX4 010-3A
1NA
3
4
3TX4 010-2A
1NF2
13TX4 001-2A
Blocos aditivos para 3TH20
2NA
53
54
63
64
3TX4 420-2A
3TX4 431-2A
3NA + 1NF
53
54
61
62
83
84
73
74
4NA
53
54
63
64
73
74
83
84
3TX4 440-2A
3TX4 411-2G
1NA + 1NF(prolongado)
57
58
65
66
Contatores auxiliares 3TH40
4NA14
A1
A2
13
24
23
44
43
34
333TH40 40
2NA + 2NF
3TH40 22
14
A1
A2
13
22
21
44
43
32
31
4NF14
13
22
21
42
41
32
31
A1
A2
3TH40 04
1NA + 3NF14
13
22
21
42
41
32
31
A1
A2
3TH40 13
3NA + 1NF14
A1
A2
13
22
21
44
43
34
333TH40 31
8NA
13
14
23
24
33
34
43
44
53
54
63
64
73
74
83
84
A1
A2
3TH42 80
5NA + 3NF
13
14
23
24
33
34
43
44
53
54
61
62
71
72
81
82
A1
A2
3TH42 53
7NA + 1NF
13
14
23
24
33
34
43
44
53
54
61
62
73
74
83
84
A1
A2
3TH42 71
4NA + 4NF
13
14
23
24
33
34
43
44
51
52
61
62
71
72
81
82
A1
A2
3TH42 44
3TH42 6213
14
23
24
33
34
43
44
53
54
61
62
71
72
83
84
A1
A2
6NA + 2NF
3NA + 3NF e 1NA + 1NF (prolongado)
13 23 33 47 51 61 71 85
14 24 34 48 52 62 72 86
A1
A2
3TH42 93
Contatores auxiliares 3TH43, 3TH44
7NA + 3NF
3TH43 7313
14
23
24
33
34
43
44
53
54
63
64
71
72
81
82
91
92
03
04
A1
A2
10NA
13
14
23
24
33
34
43
44
53
54
63
64
73
74
83
84
93
94
03
04
A1
A2
3TH43 10
6NA + 2NF e 1NA + 1NF (prolongado)
13
14
23
24
37
38
43
44
53
54
63
64
71
72
85
86
91
92
03
04
A1
A2
3TH43 46
9NA + 1NF
A1
A2
13
14
23
24
33
34
43
44
53
54
63
64
71
72
83
84
93
94
03
04
3TH43 91
6NA + 4NF
13
14
23
24
33
34
43
44
53
54
63
64
71
72
81
82
91
92
01
02
A1
A2
3TH43 64
4NA + 4NF e 1NA + 1NF (prolongado)
A1
A2
13
14
23
24
37
38
43
44
53
54
61
62
71
72
85
86
91
92
01
02
3TH43 94
8NA + 2NF
A1
A2
13
14
23
24
33
34
43
44
53
54
63
64
71
72
83
84
91
92
03
04
3TH43 82
5NA + 5NF
A1
A2
13
14
23
24
33
34
43
44
53
54
61
62
71
72
81
82
91
92
01
02
3TH43 55
5NA + 4NF
A1
A2
13
14
23
24
33
34
43
44
53
54
61
62
71
72
81
82
91
92E2
E1
�+
3TH44 54
3TX4 422-2A
2NA + 2NF
53
54
61
62
71
72
83
84
3TX4 402-2A
2NF
51
52
61
621NA(prolongado)
3TX4 010-4A7
81NF(prolongado)
3TX4 001-4A
6
5
Esquemas de ligação
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Dados técnicos Dados técnicos
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Março 98
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Sede Central
São Paulo:Av. Mutinga, 3800Pirituba 05110-901b (011) 836-2211n (11) 81006m (011) 836-2631
Central de AtendimentoSiemensb 0800-119484
Vendas
São Paulo:b (011) 833-4450m (011) 833-4790/
833-4791
Campinas:b (019) 754-6100m (019) 754-6111
Rio de Janeiro:b (021) 583-3379m (021) 583-3474
Porto Alegre:b (051) 337-4242m (051) 337-4464
Belo Horizonte:b (031) 289-4400m (031) 289-4444
Curitiba:b (041) 360-1172m (041) 360-1170
Recife:b (081) 461-6200m (081) 461-6276
Brasília:b (061) 348-7640m (061) 348-7639
Florianópolis:b (048) 224-2010m (048) 224-3130
Salvador:b (071) 352-1800m (071) 352-1877
Fortaleza:b (085) 261-7855m (085) 244-1650
ASI 2/1497-FONº do pedido1.020.006.1
Siemens Ltda As informações aqui contidas correspondem ao estado atual da técnica, e estão sujeitas a alterações
Produtos e Sistemas Industriais,Prediais e AutomaçãoSiemens
Tempos de manobra 1)
Tempo total de abertura = tempo de abertura + duração do arco.
(Valores válidos até uma tensão inferior de 20 % e até uma sobretensãode 10% da nominal para bobinas no estado frio ou em serviço normal).
3TH20Acionamento em corrente alternada
na ligação – contato NA (ms) 5-20NF 4-12
no desligamento – contato NA 3-24NF 3-20
duração do arco 10
Acionamento em corrente contínuana ligação – contato NA (ms) 16-140
NF 13-40no desligamento – contato NA 3-6
NF 4-10duração do arco 10
3TH20 para interfaceAcionamento em corrente contínua
na ligação com 17V – contato NA (ms) 41-83NF 5-8
com 24 V – contato NA 26-37NF 5-7
com 30 V – contato NA 18-28NF 2-7
no desligamento com 17 a 30 V– contato NA 3-5
NF 17-50
3TH3, 3TH40, 3TH42, 3TH43Acionamento em corrente alternada
na ligação – contato NA (ms) 8-35NF 6-20
no desligamento – contato NA 4-18NF 5-30
duração do arco 10
Acionamento em corrente contínuana ligação – contato NA (ms) 20-170
NF 18-110no desligamento – contato NA 10-25
NF 15-30
duração do arco 10
3TH44Acionamento em corrente alternadaDuração do sinal de comando
na ligação (ms) 40 (mínimo)no desligamento 30 (mínimo)
Normas IEC 947 e VDE 0660
Tensão nominal de isolamento 1) (V) 690
Temperatura ambiente (°C) – 25 até + 55
Durabilidade mecânica (manobras)
3TH20Acionamento em corrente alternada 10 x 10 6
Acionamento em corrente contínua 30 x 10 6
Bloco aditivo de contatos auxiliares 10 x 10 6
3TH3Acionamento em corrente alternada eacionamento em corrente contínua 30 x 10 6
Bloco aditivo de contatos auxiliares 10 x 10 6
3TH4 Acionamento em corrente alternada eacionamento em corrente contínua 30 x 10 6
Frequência de manobra (m/h)
3TH20em AC-15/AC-14 e DC-13 1200
3TH3, 3TH4em AC-15/AC-14 e DC-13 3600
Grau de proteção IP00 (sem invólucro)IP20 (nas conexões)Proteção ao toqueacidental.
Consumo das bobinas(no estado frio com 1,0 x Us)
3TH20Acionamento em corrente alternada 60 Hz 50Hz
na ligação (VA) 14,4 15(cos �) 0,36 0,41
permanente (VA) 6,1 6,8(cos �) 0,46 0,42
Acionamento em corrente contínuana ligação e permanente (W) 3 / 1,2 2)
3TH3, 3TH4Acionamento em corrente alternada 60 Hz 50Hz
na ligação (VA) 87 68(cos �) 0,79 0,82
permanente (VA) 12 10(cos �) 0,3 0,29
Acionamento em corrente alternada 60 / 50 Hz
na ligação (VA) 71 / 77(cos �) 0,75 / 0,81
permanente (VA) 9 / 11(cos �) 0,27 / 0,28
Acionamento em corrente contínua
na ligação e permanente (W) 6,2
3TH44 (bobina do bloqueio mecânico)Acionamento em corrente alternada
no desligamento (VA) 110(cos a) 0,86
Faixa de operação das bobinas
3TH20, 3TH3, 3TH4 0,8 até 1,1 X Us
3TH20 (para interface) 0,8 até 1,7 X Us
Contatos
Característica técnica: Em ponte e duplo, apresentam altaconfiabilidade de contato.
Correntes nominais
3TH20Corrente alternada
Ie / AC-12 (A) 10Ie / AC-15 / AC-14 220 / 230V (A) 4
380 / 400V 3Corrente contínua
Ie / DC-12 24V (A) 4 (10)(os valores entre parênteses 48V 2,2 (10)são para três polos em série) 110V 1,1 (6)
125V 0,9 (5,1)Ie / DC-13 24V (A) 2,1 (10)(os valores entre parênteses 48V 1,1 (5,5)são para três polos em série) 110V 0,52 (3)
125V 0,45 (2,5)
3TH3, 3TH4Corrente alternada
Ie / AC-12 (A) 16Ie / AC-15 / AC-14 220 / 230V (A) 10
380 / 400V 6Corrente contínua
Ie / DC-12 24V (A) 10 (10)(os valores entre parênteses 48V 10 (10)são para três polos em série) 110V 2,1 (10)
125V 1,8 (10)220V 0,8 (10)
Ie / DC-13 24V (A) 10 (10)(os valores entre parênteses 48V 5 (10)são para três polos em série) 110V 0,9 (10)
125V 0,8 (10)220V 0,45 (2)
Bloco aditivo de contatos para 3TH3Corrente alternada
Ie / AC-12 (A) 10Ie / AC-15 / AC-14 220 / 230V (A) 6
380 / 400V 4Corrente contínua
Ie / DC-12 24V (A) 10 (10)(os valores entre parênteses 48V 10 (10)são para três polos em série) 110V 0,98 (10)
125V 0,86 (10)220V 0,37 (10)
Ie / DC-13 24V (A) 10 (10)(os valores entre parênteses 48V 4,6 (10)são para três polos em série) 110V 0,8 (10)
125V 0,7 (10)220V 0,3 (2)
Montagem
3TH20 – permite montagem em qualquer posição
3TH3, 3TH40, 3TH42, 3TH43Acionamento em Acionamento emcorrente alternada corrente contínua
3TH44Acionamento em corrente alternada
Durabilidade elétrica dos contatos
Contatores 3TH20 e bloco aditivo de contatos
Contatores 3TH3, 3TH4
Bloco aditivo de contatos para 3TH3
1) Com o uso de supressores de sobretensão os tempos se alteram em: 6 a 10 vezes com diodo 2 a 6 vezes com RC.+ 2 a + 5 ms com varistor.
0,01
Man
obra
s (1
06 )
Corrente de interrupção (A)
0,050,1
0,51235
10
30
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 7 10
AC-15/AC-14220/230V
DC-13220V
DC-13110V
DC-1324V
0,01
Man
obra
s (1
06 )
Corrente de interrupção (A)
0,5
1
23
5
10
30
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 7 10
DC-13110V
4
DC-13220V
DC-1324V
AC-15/AC-14220/230V
22,5° 22,5°22,5° 22,5°
0,01
Man
obra
s (1
06 )
Corrente de interrupção (A)
0,5
1
23
5
10
30
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 7 10
4 DC-13220V
AC-15/AC-14220/230V
DC-1324V
DC-13110V
22,5° 22,5°
90° 90°
22,5° 22,5°
1) Bloco aditivo 3TX4 para 3TH20 até 500V2) Contator 3TH20 para interface
Contatores auxiliares 3TH20, 3TH3
Contatores auxiliares 3TH42
Blocos aditivos para 3TH3
2NA + 2NF
14
A1
A2
13
22
21
44
43
32
31
3TH20 223TH30 22
3NA + 1NF
14
A1
A2
13
22
21
44
43
34
33
3TH20 313TH30 31
4NA14
A1
A2
13
24
23
44
43
34
33
3TH20 403TH30 40
1NA(com indicador de estado ligado-desligado)
3
4
3TX4 010-3A
1NA
3
4
3TX4 010-2A
1NF2
13TX4 001-2A
Blocos aditivos para 3TH20
2NA
53
54
63
64
3TX4 420-2A
3TX4 431-2A
3NA + 1NF
53
54
61
62
83
84
73
74
4NA
53
54
63
64
73
74
83
84
3TX4 440-2A
3TX4 411-2G
1NA + 1NF(prolongado)
57
58
65
66
Contatores auxiliares 3TH40
4NA14
A1
A2
13
24
23
44
43
34
333TH40 40
2NA + 2NF
3TH40 22
14
A1
A2
13
22
21
44
43
32
31
4NF14
13
22
21
42
41
32
31
A1
A2
3TH40 04
1NA + 3NF14
13
22
21
42
41
32
31
A1
A2
3TH40 13
3NA + 1NF14
A1
A2
13
22
21
44
43
34
333TH40 31
8NA
13
14
23
24
33
34
43
44
53
54
63
64
73
74
83
84
A1
A2
3TH42 80
5NA + 3NF
13
14
23
24
33
34
43
44
53
54
61
62
71
72
81
82
A1
A2
3TH42 53
7NA + 1NF
13
14
23
24
33
34
43
44
53
54
61
62
73
74
83
84
A1
A2
3TH42 71
4NA + 4NF
13
14
23
24
33
34
43
44
51
52
61
62
71
72
81
82
A1
A2
3TH42 44
3TH42 6213
14
23
24
33
34
43
44
53
54
61
62
71
72
83
84
A1
A2
6NA + 2NF
3NA + 3NF e 1NA + 1NF (prolongado)
13 23 33 47 51 61 71 85
14 24 34 48 52 62 72 86
A1
A2
3TH42 93
Contatores auxiliares 3TH43, 3TH44
7NA + 3NF
3TH43 7313
14
23
24
33
34
43
44
53
54
63
64
71
72
81
82
91
92
03
04
A1
A2
10NA
13
14
23
24
33
34
43
44
53
54
63
64
73
74
83
84
93
94
03
04
A1
A2
3TH43 10
6NA + 2NF e 1NA + 1NF (prolongado)
13
14
23
24
37
38
43
44
53
54
63
64
71
72
85
86
91
92
03
04
A1
A2
3TH43 46
9NA + 1NF
A1
A2
13
14
23
24
33
34
43
44
53
54
63
64
71
72
83
84
93
94
03
04
3TH43 91
6NA + 4NF
13
14
23
24
33
34
43
44
53
54
63
64
71
72
81
82
91
92
01
02
A1
A2
3TH43 64
4NA + 4NF e 1NA + 1NF (prolongado)
A1
A2
13
14
23
24
37
38
43
44
53
54
61
62
71
72
85
86
91
92
01
02
3TH43 94
8NA + 2NF
A1
A2
13
14
23
24
33
34
43
44
53
54
63
64
71
72
83
84
91
92
03
04
3TH43 82
5NA + 5NF
A1
A2
13
14
23
24
33
34
43
44
53
54
61
62
71
72
81
82
91
92
01
02
3TH43 55
5NA + 4NF
A1
A2
13
14
23
24
33
34
43
44
53
54
61
62
71
72
81
82
91
92E2
E1
�+
3TH44 54
3TX4 422-2A
2NA + 2NF
53
54
61
62
71
72
83
84
3TX4 402-2A
2NF
51
52
61
621NA(prolongado)
3TX4 010-4A7
81NF(prolongado)
3TX4 001-4A
6
5
Esquemas de ligação
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Dados técnicos Dados técnicos
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Março 98
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Sede Central
São Paulo:Av. Mutinga, 3800Pirituba 05110-901b (011) 836-2211n (11) 81006m (011) 836-2631
Central de AtendimentoSiemensb 0800-119484
Vendas
São Paulo:b (011) 833-4450m (011) 833-4790/
833-4791
Campinas:b (019) 754-6100m (019) 754-6111
Rio de Janeiro:b (021) 583-3379m (021) 583-3474
Porto Alegre:b (051) 337-4242m (051) 337-4464
Belo Horizonte:b (031) 289-4400m (031) 289-4444
Curitiba:b (041) 360-1172m (041) 360-1170
Recife:b (081) 461-6200m (081) 461-6276
Brasília:b (061) 348-7640m (061) 348-7639
Florianópolis:b (048) 224-2010m (048) 224-3130
Salvador:b (071) 352-1800m (071) 352-1877
Fortaleza:b (085) 261-7855m (085) 244-1650
ASI 2/1497-FONº do pedido1.020.006.1
Siemens Ltda As informações aqui contidas correspondem ao estado atual da técnica, e estão sujeitas a alterações
Produtos e Sistemas Industriais,Prediais e AutomaçãoSiemens
Tempos de manobra 1)
Tempo total de abertura = tempo de abertura + duração do arco.
(Valores válidos até uma tensão inferior de 20 % e até uma sobretensãode 10% da nominal para bobinas no estado frio ou em serviço normal).
3TH20Acionamento em corrente alternada
na ligação – contato NA (ms) 5-20NF 4-12
no desligamento – contato NA 3-24NF 3-20
duração do arco 10
Acionamento em corrente contínuana ligação – contato NA (ms) 16-140
NF 13-40no desligamento – contato NA 3-6
NF 4-10duração do arco 10
3TH20 para interfaceAcionamento em corrente contínua
na ligação com 17V – contato NA (ms) 41-83NF 5-8
com 24 V – contato NA 26-37NF 5-7
com 30 V – contato NA 18-28NF 2-7
no desligamento com 17 a 30 V– contato NA 3-5
NF 17-50
3TH3, 3TH40, 3TH42, 3TH43Acionamento em corrente alternada
na ligação – contato NA (ms) 8-35NF 6-20
no desligamento – contato NA 4-18NF 5-30
duração do arco 10
Acionamento em corrente contínuana ligação – contato NA (ms) 20-170
NF 18-110no desligamento – contato NA 10-25
NF 15-30
duração do arco 10
3TH44Acionamento em corrente alternadaDuração do sinal de comando
na ligação (ms) 40 (mínimo)no desligamento 30 (mínimo)
Normas IEC 947 e VDE 0660
Tensão nominal de isolamento 1) (V) 690
Temperatura ambiente (°C) – 25 até + 55
Durabilidade mecânica (manobras)
3TH20Acionamento em corrente alternada 10 x 10 6
Acionamento em corrente contínua 30 x 10 6
Bloco aditivo de contatos auxiliares 10 x 10 6
3TH3Acionamento em corrente alternada eacionamento em corrente contínua 30 x 10 6
Bloco aditivo de contatos auxiliares 10 x 10 6
3TH4 Acionamento em corrente alternada eacionamento em corrente contínua 30 x 10 6
Frequência de manobra (m/h)
3TH20em AC-15/AC-14 e DC-13 1200
3TH3, 3TH4em AC-15/AC-14 e DC-13 3600
Grau de proteção IP00 (sem invólucro)IP20 (nas conexões)Proteção ao toqueacidental.
Consumo das bobinas(no estado frio com 1,0 x Us)
3TH20Acionamento em corrente alternada 60 Hz 50Hz
na ligação (VA) 14,4 15(cos �) 0,36 0,41
permanente (VA) 6,1 6,8(cos �) 0,46 0,42
Acionamento em corrente contínuana ligação e permanente (W) 3 / 1,2 2)
3TH3, 3TH4Acionamento em corrente alternada 60 Hz 50Hz
na ligação (VA) 87 68(cos �) 0,79 0,82
permanente (VA) 12 10(cos �) 0,3 0,29
Acionamento em corrente alternada 60 / 50 Hz
na ligação (VA) 71 / 77(cos �) 0,75 / 0,81
permanente (VA) 9 / 11(cos �) 0,27 / 0,28
Acionamento em corrente contínua
na ligação e permanente (W) 6,2
3TH44 (bobina do bloqueio mecânico)Acionamento em corrente alternada
no desligamento (VA) 110(cos a) 0,86
Faixa de operação das bobinas
3TH20, 3TH3, 3TH4 0,8 até 1,1 X Us
3TH20 (para interface) 0,8 até 1,7 X Us
Contatos
Característica técnica: Em ponte e duplo, apresentam altaconfiabilidade de contato.
Correntes nominais
3TH20Corrente alternada
Ie / AC-12 (A) 10Ie / AC-15 / AC-14 220 / 230V (A) 4
380 / 400V 3Corrente contínua
Ie / DC-12 24V (A) 4 (10)(os valores entre parênteses 48V 2,2 (10)são para três polos em série) 110V 1,1 (6)
125V 0,9 (5,1)Ie / DC-13 24V (A) 2,1 (10)(os valores entre parênteses 48V 1,1 (5,5)são para três polos em série) 110V 0,52 (3)
125V 0,45 (2,5)
3TH3, 3TH4Corrente alternada
Ie / AC-12 (A) 16Ie / AC-15 / AC-14 220 / 230V (A) 10
380 / 400V 6Corrente contínua
Ie / DC-12 24V (A) 10 (10)(os valores entre parênteses 48V 10 (10)são para três polos em série) 110V 2,1 (10)
125V 1,8 (10)220V 0,8 (10)
Ie / DC-13 24V (A) 10 (10)(os valores entre parênteses 48V 5 (10)são para três polos em série) 110V 0,9 (10)
125V 0,8 (10)220V 0,45 (2)
Bloco aditivo de contatos para 3TH3Corrente alternada
Ie / AC-12 (A) 10Ie / AC-15 / AC-14 220 / 230V (A) 6
380 / 400V 4Corrente contínua
Ie / DC-12 24V (A) 10 (10)(os valores entre parênteses 48V 10 (10)são para três polos em série) 110V 0,98 (10)
125V 0,86 (10)220V 0,37 (10)
Ie / DC-13 24V (A) 10 (10)(os valores entre parênteses 48V 4,6 (10)são para três polos em série) 110V 0,8 (10)
125V 0,7 (10)220V 0,3 (2)
Montagem
3TH20 – permite montagem em qualquer posição
3TH3, 3TH40, 3TH42, 3TH43Acionamento em Acionamento emcorrente alternada corrente contínua
3TH44Acionamento em corrente alternada
Durabilidade elétrica dos contatos
Contatores 3TH20 e bloco aditivo de contatos
Contatores 3TH3, 3TH4
Bloco aditivo de contatos para 3TH3
1) Com o uso de supressores de sobretensão os tempos se alteram em: 6 a 10 vezes com diodo 2 a 6 vezes com RC.+ 2 a + 5 ms com varistor.
0,01
Man
obra
s (1
06 )
Corrente de interrupção (A)
0,050,1
0,51235
10
30
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 7 10
AC-15/AC-14220/230V
DC-13220V
DC-13110V
DC-1324V
0,01
Man
obra
s (1
06 )
Corrente de interrupção (A)
0,5
1
23
5
10
30
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 7 10
DC-13110V
4
DC-13220V
DC-1324V
AC-15/AC-14220/230V
22,5° 22,5°22,5° 22,5°
0,01
Man
obra
s (1
06 )
Corrente de interrupção (A)
0,5
1
23
5
10
30
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 7 10
4 DC-13220V
AC-15/AC-14220/230V
DC-1324V
DC-13110V
22,5° 22,5°
90° 90°
22,5° 22,5°
1) Bloco aditivo 3TX4 para 3TH20 até 500V2) Contator 3TH20 para interface
Contatores auxiliares 3TH20, 3TH3
Contatores auxiliares 3TH42
Blocos aditivos para 3TH3
2NA + 2NF
14
A1
A2
13
22
21
44
43
32
31
3TH20 223TH30 22
3NA + 1NF
14
A1
A2
13
22
21
44
43
34
33
3TH20 313TH30 31
4NA14
A1
A2
13
24
23
44
43
34
33
3TH20 403TH30 40
1NA(com indicador de estado ligado-desligado)
3
4
3TX4 010-3A
1NA
3
4
3TX4 010-2A
1NF2
13TX4 001-2A
Blocos aditivos para 3TH20
2NA
53
54
63
64
3TX4 420-2A
3TX4 431-2A
3NA + 1NF
53
54
61
62
83
84
73
74
4NA
53
54
63
64
73
74
83
84
3TX4 440-2A
3TX4 411-2G
1NA + 1NF(prolongado)
57
58
65
66
Contatores auxiliares 3TH40
4NA14
A1
A2
13
24
23
44
43
34
333TH40 40
2NA + 2NF
3TH40 22
14
A1
A2
13
22
21
44
43
32
31
4NF14
13
22
21
42
41
32
31
A1
A2
3TH40 04
1NA + 3NF14
13
22
21
42
41
32
31
A1
A2
3TH40 13
3NA + 1NF14
A1
A2
13
22
21
44
43
34
333TH40 31
8NA
13
14
23
24
33
34
43
44
53
54
63
64
73
74
83
84
A1
A2
3TH42 80
5NA + 3NF
13
14
23
24
33
34
43
44
53
54
61
62
71
72
81
82
A1
A2
3TH42 53
7NA + 1NF
13
14
23
24
33
34
43
44
53
54
61
62
73
74
83
84
A1
A2
3TH42 71
4NA + 4NF
13
14
23
24
33
34
43
44
51
52
61
62
71
72
81
82
A1
A2
3TH42 44
3TH42 6213
14
23
24
33
34
43
44
53
54
61
62
71
72
83
84
A1
A2
6NA + 2NF
3NA + 3NF e 1NA + 1NF (prolongado)
13 23 33 47 51 61 71 85
14 24 34 48 52 62 72 86
A1
A2
3TH42 93
Contatores auxiliares 3TH43, 3TH44
7NA + 3NF
3TH43 7313
14
23
24
33
34
43
44
53
54
63
64
71
72
81
82
91
92
03
04
A1
A2
10NA
13
14
23
24
33
34
43
44
53
54
63
64
73
74
83
84
93
94
03
04
A1
A2
3TH43 10
6NA + 2NF e 1NA + 1NF (prolongado)
13
14
23
24
37
38
43
44
53
54
63
64
71
72
85
86
91
92
03
04
A1
A2
3TH43 46
9NA + 1NF
A1
A2
13
14
23
24
33
34
43
44
53
54
63
64
71
72
83
84
93
94
03
04
3TH43 91
6NA + 4NF
13
14
23
24
33
34
43
44
53
54
63
64
71
72
81
82
91
92
01
02
A1
A2
3TH43 64
4NA + 4NF e 1NA + 1NF (prolongado)
A1
A2
13
14
23
24
37
38
43
44
53
54
61
62
71
72
85
86
91
92
01
02
3TH43 94
8NA + 2NF
A1
A2
13
14
23
24
33
34
43
44
53
54
63
64
71
72
83
84
91
92
03
04
3TH43 82
5NA + 5NF
A1
A2
13
14
23
24
33
34
43
44
53
54
61
62
71
72
81
82
91
92
01
02
3TH43 55
5NA + 4NF
A1
A2
13
14
23
24
33
34
43
44
53
54
61
62
71
72
81
82
91
92E2
E1
�+
3TH44 54
3TX4 422-2A
2NA + 2NF
53
54
61
62
71
72
83
84
3TX4 402-2A
2NF
51
52
61
621NA(prolongado)
3TX4 010-4A7
81NF(prolongado)
3TX4 001-4A
6
5
Esquemas de ligação
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Dados técnicos Dados técnicos
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Março 98
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Sede Central
São Paulo:Av. Mutinga, 3800Pirituba 05110-901b (011) 836-2211n (11) 81006m (011) 836-2631
Central de AtendimentoSiemensb 0800-119484
Vendas
São Paulo:b (011) 833-4450m (011) 833-4790/
833-4791
Campinas:b (019) 754-6100m (019) 754-6111
Rio de Janeiro:b (021) 583-3379m (021) 583-3474
Porto Alegre:b (051) 337-4242m (051) 337-4464
Belo Horizonte:b (031) 289-4400m (031) 289-4444
Curitiba:b (041) 360-1172m (041) 360-1170
Recife:b (081) 461-6200m (081) 461-6276
Brasília:b (061) 348-7640m (061) 348-7639
Florianópolis:b (048) 224-2010m (048) 224-3130
Salvador:b (071) 352-1800m (071) 352-1877
Fortaleza:b (085) 261-7855m (085) 244-1650
ASI 2/1497-FONº do pedido1.020.006.1
Siemens Ltda As informações aqui contidas correspondem ao estado atual da técnica, e estão sujeitas a alterações
Produtos e Sistemas Industriais,Prediais e AutomaçãoSiemens
Tempos de manobra 1)
Tempo total de abertura = tempo de abertura + duração do arco.
(Valores válidos até uma tensão inferior de 20 % e até uma sobretensãode 10% da nominal para bobinas no estado frio ou em serviço normal).
3TH20Acionamento em corrente alternada
na ligação – contato NA (ms) 5-20NF 4-12
no desligamento – contato NA 3-24NF 3-20
duração do arco 10
Acionamento em corrente contínuana ligação – contato NA (ms) 16-140
NF 13-40no desligamento – contato NA 3-6
NF 4-10duração do arco 10
3TH20 para interfaceAcionamento em corrente contínua
na ligação com 17V – contato NA (ms) 41-83NF 5-8
com 24 V – contato NA 26-37NF 5-7
com 30 V – contato NA 18-28NF 2-7
no desligamento com 17 a 30 V– contato NA 3-5
NF 17-50
3TH3, 3TH40, 3TH42, 3TH43Acionamento em corrente alternada
na ligação – contato NA (ms) 8-35NF 6-20
no desligamento – contato NA 4-18NF 5-30
duração do arco 10
Acionamento em corrente contínuana ligação – contato NA (ms) 20-170
NF 18-110no desligamento – contato NA 10-25
NF 15-30
duração do arco 10
3TH44Acionamento em corrente alternadaDuração do sinal de comando
na ligação (ms) 40 (mínimo)no desligamento 30 (mínimo)
Normas IEC 947 e VDE 0660
Tensão nominal de isolamento 1) (V) 690
Temperatura ambiente (°C) – 25 até + 55
Durabilidade mecânica (manobras)
3TH20Acionamento em corrente alternada 10 x 10 6
Acionamento em corrente contínua 30 x 10 6
Bloco aditivo de contatos auxiliares 10 x 10 6
3TH3Acionamento em corrente alternada eacionamento em corrente contínua 30 x 10 6
Bloco aditivo de contatos auxiliares 10 x 10 6
3TH4 Acionamento em corrente alternada eacionamento em corrente contínua 30 x 10 6
Frequência de manobra (m/h)
3TH20em AC-15/AC-14 e DC-13 1200
3TH3, 3TH4em AC-15/AC-14 e DC-13 3600
Grau de proteção IP00 (sem invólucro)IP20 (nas conexões)Proteção ao toqueacidental.
Consumo das bobinas(no estado frio com 1,0 x Us)
3TH20Acionamento em corrente alternada 60 Hz 50Hz
na ligação (VA) 14,4 15(cos �) 0,36 0,41
permanente (VA) 6,1 6,8(cos �) 0,46 0,42
Acionamento em corrente contínuana ligação e permanente (W) 3 / 1,2 2)
3TH3, 3TH4Acionamento em corrente alternada 60 Hz 50Hz
na ligação (VA) 87 68(cos �) 0,79 0,82
permanente (VA) 12 10(cos �) 0,3 0,29
Acionamento em corrente alternada 60 / 50 Hz
na ligação (VA) 71 / 77(cos �) 0,75 / 0,81
permanente (VA) 9 / 11(cos �) 0,27 / 0,28
Acionamento em corrente contínua
na ligação e permanente (W) 6,2
3TH44 (bobina do bloqueio mecânico)Acionamento em corrente alternada
no desligamento (VA) 110(cos a) 0,86
Faixa de operação das bobinas
3TH20, 3TH3, 3TH4 0,8 até 1,1 X Us
3TH20 (para interface) 0,8 até 1,7 X Us
Contatos
Característica técnica: Em ponte e duplo, apresentam altaconfiabilidade de contato.
Correntes nominais
3TH20Corrente alternada
Ie / AC-12 (A) 10Ie / AC-15 / AC-14 220 / 230V (A) 4
380 / 400V 3Corrente contínua
Ie / DC-12 24V (A) 4 (10)(os valores entre parênteses 48V 2,2 (10)são para três polos em série) 110V 1,1 (6)
125V 0,9 (5,1)Ie / DC-13 24V (A) 2,1 (10)(os valores entre parênteses 48V 1,1 (5,5)são para três polos em série) 110V 0,52 (3)
125V 0,45 (2,5)
3TH3, 3TH4Corrente alternada
Ie / AC-12 (A) 16Ie / AC-15 / AC-14 220 / 230V (A) 10
380 / 400V 6Corrente contínua
Ie / DC-12 24V (A) 10 (10)(os valores entre parênteses 48V 10 (10)são para três polos em série) 110V 2,1 (10)
125V 1,8 (10)220V 0,8 (10)
Ie / DC-13 24V (A) 10 (10)(os valores entre parênteses 48V 5 (10)são para três polos em série) 110V 0,9 (10)
125V 0,8 (10)220V 0,45 (2)
Bloco aditivo de contatos para 3TH3Corrente alternada
Ie / AC-12 (A) 10Ie / AC-15 / AC-14 220 / 230V (A) 6
380 / 400V 4Corrente contínua
Ie / DC-12 24V (A) 10 (10)(os valores entre parênteses 48V 10 (10)são para três polos em série) 110V 0,98 (10)
125V 0,86 (10)220V 0,37 (10)
Ie / DC-13 24V (A) 10 (10)(os valores entre parênteses 48V 4,6 (10)são para três polos em série) 110V 0,8 (10)
125V 0,7 (10)220V 0,3 (2)
Montagem
3TH20 – permite montagem em qualquer posição
3TH3, 3TH40, 3TH42, 3TH43Acionamento em Acionamento emcorrente alternada corrente contínua
3TH44Acionamento em corrente alternada
Durabilidade elétrica dos contatos
Contatores 3TH20 e bloco aditivo de contatos
Contatores 3TH3, 3TH4
Bloco aditivo de contatos para 3TH3
1) Com o uso de supressores de sobretensão os tempos se alteram em: 6 a 10 vezes com diodo 2 a 6 vezes com RC.+ 2 a + 5 ms com varistor.
0,01
Man
obra
s (1
06 )
Corrente de interrupção (A)
0,050,1
0,51235
10
30
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 7 10
AC-15/AC-14220/230V
DC-13220V
DC-13110V
DC-1324V
0,01
Man
obra
s (1
06 )
Corrente de interrupção (A)
0,5
1
23
5
10
30
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 7 10
DC-13110V
4
DC-13220V
DC-1324V
AC-15/AC-14220/230V
22,5° 22,5°22,5° 22,5°
0,01
Man
obra
s (1
06 )
Corrente de interrupção (A)
0,5
1
23
5
10
30
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 7 10
4 DC-13220V
AC-15/AC-14220/230V
DC-1324V
DC-13110V
22,5° 22,5°
90° 90°
22,5° 22,5°
1) Bloco aditivo 3TX4 para 3TH20 até 500V2) Contator 3TH20 para interface
Contatores auxiliares 3TH20, 3TH3
Contatores auxiliares 3TH42
Blocos aditivos para 3TH3
2NA + 2NF
14
A1
A2
13
22
21
44
43
32
31
3TH20 223TH30 22
3NA + 1NF
14
A1
A2
13
22
21
44
43
34
33
3TH20 313TH30 31
4NA14
A1
A2
13
24
23
44
43
34
33
3TH20 403TH30 40
1NA(com indicador de estado ligado-desligado)
3
4
3TX4 010-3A
1NA
3
4
3TX4 010-2A
1NF2
13TX4 001-2A
Blocos aditivos para 3TH20
2NA
53
54
63
64
3TX4 420-2A
3TX4 431-2A
3NA + 1NF
53
54
61
62
83
84
73
74
4NA
53
54
63
64
73
74
83
84
3TX4 440-2A
3TX4 411-2G
1NA + 1NF(prolongado)
57
58
65
66
Contatores auxiliares 3TH40
4NA14
A1
A2
13
24
23
44
43
34
333TH40 40
2NA + 2NF
3TH40 22
14
A1
A2
13
22
21
44
43
32
31
4NF14
13
22
21
42
41
32
31
A1
A2
3TH40 04
1NA + 3NF14
13
22
21
42
41
32
31
A1
A2
3TH40 13
3NA + 1NF14
A1
A2
13
22
21
44
43
34
333TH40 31
8NA
13
14
23
24
33
34
43
44
53
54
63
64
73
74
83
84
A1
A2
3TH42 80
5NA + 3NF
13
14
23
24
33
34
43
44
53
54
61
62
71
72
81
82
A1
A2
3TH42 53
7NA + 1NF
13
14
23
24
33
34
43
44
53
54
61
62
73
74
83
84
A1
A2
3TH42 71
4NA + 4NF
13
14
23
24
33
34
43
44
51
52
61
62
71
72
81
82
A1
A2
3TH42 44
3TH42 6213
14
23
24
33
34
43
44
53
54
61
62
71
72
83
84
A1
A2
6NA + 2NF
3NA + 3NF e 1NA + 1NF (prolongado)
13 23 33 47 51 61 71 85
14 24 34 48 52 62 72 86
A1
A2
3TH42 93
Contatores auxiliares 3TH43, 3TH44
7NA + 3NF
3TH43 7313
14
23
24
33
34
43
44
53
54
63
64
71
72
81
82
91
92
03
04
A1
A2
10NA
13
14
23
24
33
34
43
44
53
54
63
64
73
74
83
84
93
94
03
04
A1
A2
3TH43 10
6NA + 2NF e 1NA + 1NF (prolongado)
13
14
23
24
37
38
43
44
53
54
63
64
71
72
85
86
91
92
03
04
A1
A2
3TH43 46
9NA + 1NF
A1
A2
13
14
23
24
33
34
43
44
53
54
63
64
71
72
83
84
93
94
03
04
3TH43 91
6NA + 4NF
13
14
23
24
33
34
43
44
53
54
63
64
71
72
81
82
91
92
01
02
A1
A2
3TH43 64
4NA + 4NF e 1NA + 1NF (prolongado)
A1
A2
13
14
23
24
37
38
43
44
53
54
61
62
71
72
85
86
91
92
01
02
3TH43 94
8NA + 2NF
A1
A2
13
14
23
24
33
34
43
44
53
54
63
64
71
72
83
84
91
92
03
04
3TH43 82
5NA + 5NF
A1
A2
13
14
23
24
33
34
43
44
53
54
61
62
71
72
81
82
91
92
01
02
3TH43 55
5NA + 4NF
A1
A2
13
14
23
24
33
34
43
44
53
54
61
62
71
72
81
82
91
92E2
E1
�+
3TH44 54
3TX4 422-2A
2NA + 2NF
53
54
61
62
71
72
83
84
3TX4 402-2A
2NF
51
52
61
621NA(prolongado)
3TX4 010-4A7
81NF(prolongado)
3TX4 001-4A
6
5
Esquemas de ligação
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Dados técnicos Dados técnicos
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Março 98
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Sede Central
São Paulo:Av. Mutinga, 3800Pirituba 05110-901b (011) 836-2211n (11) 81006m (011) 836-2631
Central de AtendimentoSiemensb 0800-119484
Vendas
São Paulo:b (011) 833-4450m (011) 833-4790/
833-4791
Campinas:b (019) 754-6100m (019) 754-6111
Rio de Janeiro:b (021) 583-3379m (021) 583-3474
Porto Alegre:b (051) 337-4242m (051) 337-4464
Belo Horizonte:b (031) 289-4400m (031) 289-4444
Curitiba:b (041) 360-1172m (041) 360-1170
Recife:b (081) 461-6200m (081) 461-6276
Brasília:b (061) 348-7640m (061) 348-7639
Florianópolis:b (048) 224-2010m (048) 224-3130
Salvador:b (071) 352-1800m (071) 352-1877
Fortaleza:b (085) 261-7855m (085) 244-1650
ASI 2/1497-FONº do pedido1.020.006.1
Siemens Ltda As informações aqui contidas correspondem ao estado atual da técnica, e estão sujeitas a alterações
Produtos e Sistemas Industriais,Prediais e AutomaçãoSiemens
Tempos de manobra 1)
Tempo total de abertura = tempo de abertura + duração do arco.
(Valores válidos até uma tensão inferior de 20 % e até uma sobretensãode 10% da nominal para bobinas no estado frio ou em serviço normal).
3TH20Acionamento em corrente alternada
na ligação – contato NA (ms) 5-20NF 4-12
no desligamento – contato NA 3-24NF 3-20
duração do arco 10
Acionamento em corrente contínuana ligação – contato NA (ms) 16-140
NF 13-40no desligamento – contato NA 3-6
NF 4-10duração do arco 10
3TH20 para interfaceAcionamento em corrente contínua
na ligação com 17V – contato NA (ms) 41-83NF 5-8
com 24 V – contato NA 26-37NF 5-7
com 30 V – contato NA 18-28NF 2-7
no desligamento com 17 a 30 V– contato NA 3-5
NF 17-50
3TH3, 3TH40, 3TH42, 3TH43Acionamento em corrente alternada
na ligação – contato NA (ms) 8-35NF 6-20
no desligamento – contato NA 4-18NF 5-30
duração do arco 10
Acionamento em corrente contínuana ligação – contato NA (ms) 20-170
NF 18-110no desligamento – contato NA 10-25
NF 15-30
duração do arco 10
3TH44Acionamento em corrente alternadaDuração do sinal de comando
na ligação (ms) 40 (mínimo)no desligamento 30 (mínimo)
Normas IEC 947 e VDE 0660
Tensão nominal de isolamento 1) (V) 690
Temperatura ambiente (°C) – 25 até + 55
Durabilidade mecânica (manobras)
3TH20Acionamento em corrente alternada 10 x 10 6
Acionamento em corrente contínua 30 x 10 6
Bloco aditivo de contatos auxiliares 10 x 10 6
3TH3Acionamento em corrente alternada eacionamento em corrente contínua 30 x 10 6
Bloco aditivo de contatos auxiliares 10 x 10 6
3TH4 Acionamento em corrente alternada eacionamento em corrente contínua 30 x 10 6
Frequência de manobra (m/h)
3TH20em AC-15/AC-14 e DC-13 1200
3TH3, 3TH4em AC-15/AC-14 e DC-13 3600
Grau de proteção IP00 (sem invólucro)IP20 (nas conexões)Proteção ao toqueacidental.
Consumo das bobinas(no estado frio com 1,0 x Us)
3TH20Acionamento em corrente alternada 60 Hz 50Hz
na ligação (VA) 14,4 15(cos �) 0,36 0,41
permanente (VA) 6,1 6,8(cos �) 0,46 0,42
Acionamento em corrente contínuana ligação e permanente (W) 3 / 1,2 2)
3TH3, 3TH4Acionamento em corrente alternada 60 Hz 50Hz
na ligação (VA) 87 68(cos �) 0,79 0,82
permanente (VA) 12 10(cos �) 0,3 0,29
Acionamento em corrente alternada 60 / 50 Hz
na ligação (VA) 71 / 77(cos �) 0,75 / 0,81
permanente (VA) 9 / 11(cos �) 0,27 / 0,28
Acionamento em corrente contínua
na ligação e permanente (W) 6,2
3TH44 (bobina do bloqueio mecânico)Acionamento em corrente alternada
no desligamento (VA) 110(cos a) 0,86
Faixa de operação das bobinas
3TH20, 3TH3, 3TH4 0,8 até 1,1 X Us
3TH20 (para interface) 0,8 até 1,7 X Us
Contatos
Característica técnica: Em ponte e duplo, apresentam altaconfiabilidade de contato.
Correntes nominais
3TH20Corrente alternada
Ie / AC-12 (A) 10Ie / AC-15 / AC-14 220 / 230V (A) 4
380 / 400V 3Corrente contínua
Ie / DC-12 24V (A) 4 (10)(os valores entre parênteses 48V 2,2 (10)são para três polos em série) 110V 1,1 (6)
125V 0,9 (5,1)Ie / DC-13 24V (A) 2,1 (10)(os valores entre parênteses 48V 1,1 (5,5)são para três polos em série) 110V 0,52 (3)
125V 0,45 (2,5)
3TH3, 3TH4Corrente alternada
Ie / AC-12 (A) 16Ie / AC-15 / AC-14 220 / 230V (A) 10
380 / 400V 6Corrente contínua
Ie / DC-12 24V (A) 10 (10)(os valores entre parênteses 48V 10 (10)são para três polos em série) 110V 2,1 (10)
125V 1,8 (10)220V 0,8 (10)
Ie / DC-13 24V (A) 10 (10)(os valores entre parênteses 48V 5 (10)são para três polos em série) 110V 0,9 (10)
125V 0,8 (10)220V 0,45 (2)
Bloco aditivo de contatos para 3TH3Corrente alternada
Ie / AC-12 (A) 10Ie / AC-15 / AC-14 220 / 230V (A) 6
380 / 400V 4Corrente contínua
Ie / DC-12 24V (A) 10 (10)(os valores entre parênteses 48V 10 (10)são para três polos em série) 110V 0,98 (10)
125V 0,86 (10)220V 0,37 (10)
Ie / DC-13 24V (A) 10 (10)(os valores entre parênteses 48V 4,6 (10)são para três polos em série) 110V 0,8 (10)
125V 0,7 (10)220V 0,3 (2)
Montagem
3TH20 – permite montagem em qualquer posição
3TH3, 3TH40, 3TH42, 3TH43Acionamento em Acionamento emcorrente alternada corrente contínua
3TH44Acionamento em corrente alternada
Durabilidade elétrica dos contatos
Contatores 3TH20 e bloco aditivo de contatos
Contatores 3TH3, 3TH4
Bloco aditivo de contatos para 3TH3
1) Com o uso de supressores de sobretensão os tempos se alteram em: 6 a 10 vezes com diodo 2 a 6 vezes com RC.+ 2 a + 5 ms com varistor.
0,01
Man
obra
s (1
06 )
Corrente de interrupção (A)
0,050,1
0,51235
10
30
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 7 10
AC-15/AC-14220/230V
DC-13220V
DC-13110V
DC-1324V
0,01
Man
obra
s (1
06 )
Corrente de interrupção (A)
0,5
1
23
5
10
30
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 7 10
DC-13110V
4
DC-13220V
DC-1324V
AC-15/AC-14220/230V
22,5° 22,5°22,5° 22,5°
0,01
Man
obra
s (1
06 )
Corrente de interrupção (A)
0,5
1
23
5
10
30
0,01 0,03 0,05 0,1 0,3 0,5 1 2 3 4 5 7 10
4 DC-13220V
AC-15/AC-14220/230V
DC-1324V
DC-13110V
22,5° 22,5°
90° 90°
22,5° 22,5°
1) Bloco aditivo 3TX4 para 3TH20 até 500V2) Contator 3TH20 para interface
NA NF NA NFprolongado
Execuções de contatos Bloco aditivo Proteção contra Seção dos condutoresde contatos curto-circuíto
(Icc ≤ 1kA)(veja combinações Fusível máximo Fio Cabo flexívelcom contatores DIAZED, com terminalabaixo) NEOZED ou NH tubular
Minidisjuntor5SX (curva C)(A) (mm2) (mm2)
1 – – – 3TX4 010-2A 16 / 10 1) 2 x (0,5 - 2,5) 2 x (0,75 - 2,5)– 1 – – 3TX4 001-2A– – 1 – 3TX4 010-4A– – – 1 3TX4 001-4A1 – – – 3TX4 010-3A
(com indicador de estado ligado desligado
Acionamento em corrente alternada4 – 3TH20 40-0A qq 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5) 45 48 68 35 40 4,43 1 3TH20 31-0A qq2 2 3TH20 22-0A qq
Acionamento em corrente contínua4 – 3TH20 40-0B qq 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5) 45 48 68 35 40 4,43 1 3TH20 31-0B qq2 2 3TH20 22-0B qq
Para interface com eletrônica industrial 1). Acionamento em corrente contínua 24 VCC. 4 – 3TH20 40-0FB4 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5) 45 48 68 35 40 4,43 1 3TH20 31-0FB42 2 3TH20 22-0FB4
1) Contatores para interface não permitem uso de bloco aditivo
Combinações de blocos aditivos com contatoresContatores auxiliares
3TH30 40-0A qq 4NA 3TH30 31-0A qq 3NA + 1NF 3TH30 22-0A qq 2NA + 2NF3TH30 40-0B qq 4NA 3TH30 31-0B qq 3NA + 1NF 3TH30 22-0B qq 2NA + 2NF
Blocos aditivos (Pode-se montar até quatro blocos aditivos. Atendendo as normas, os números de identificação dos contatos estão inscritos respectivamente, o de posição nocontator e o de função no bloco aditivo).
Combinações5NA 6NA 7NA 8NA 4NA + 1NF 5NA + 1NF 6NA + 1NF 7NA + 1NF 3NA + 2NF 4NA + 2NF 5NA + 2NF 6NA + 2NF4NA + 1NF 5NA + 1NF 6NA + 1NF 7NA + 1NF 4NA + 2NF 5NA + 2NF 6NA + 2NF 2NA + 3NF 3NA + 3NF 4NA + 3NF 5NA + 3NF
4NA + 2NF 5NA + 2NF 6NA + 2NF 4NA + 3NF 5NA + 3NF 2NA + 4NF 3NA + 4NF 4NA + 4NF4NA + 3NF 5NA + 3NF
4NA + 4NF
Acionamento em corrente alternada4 – – – 3TH40 40-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 86 35 60 4,83 1 – – 3TH40 31-0A qq
2 2 – – 3TH40 22-0A qq
1 3 – – 3TH40 13-0A qq
– 4 – – 3TH40 04-0A qq
8 – – – 3TH42 80-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 112 35 60 4,87 1 – – 3TH42 71-0A qq
6 2 – – 3TH42 62-0A qq
5 3 – – 3TH42 53-0A qq
4 4 – – 3TH42 44-0A qq
3 3 1 1 3TH42 93-0A qq
10 – – – 3TH43 10-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 55 78 112 35 60 4,89 1 – – 3TH43 91-0A qq
8 2 – – 3TH43 82-0A qq
7 3 – – 3TH43 73-0A qq
6 4 – – 3TH43 64-0A qq
5 5 – – 3TH43 55-0A qq
6 2 1 1 3TH43 46-0A qq
4 4 1 1 3TH43 94-0A qq
Acionamento em corrente continua
8 – – – 3TH42 80-0B qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 135 35 60 4,87 1 – – 3TH42 71-0B qq
6 2 – – 3TH42 62-0B qq
5 3 – – 3TH42 53-0B qq
4 4 – – 3TH42 44-0B qq
3 3 1 1 3TH42 93-0B qq
Com bloqueio mecânico (memória). Acionamento em corrente alternada
5 4 – – 3TH44 54-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 55 78 140 35 60 4,8
Execuções de contatos Contatores Proteção contra Seção dos condutores Dimensões (mm)auxiliares curto-circuíto
(Icc ≤ 1kA)Para completar Fusível máximo Fio Cabo flexível o tipo qq (tensão DIAZED, com terminale frequência) veja NEOZED ou NH tubulartabela abaixo Minidisjuntor
5SX (curva C)Fixação: rápida por engate em trilho ou
(A) (mm2) (mm2) por parafusos. Trilho de 3,5 x 7,5 mma h p x y dØ
Acionamento em corrente alternada4 – 3TH30 40-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 85 35 60 4,83 1 3TH30 31-0A qq2 2 3TH30 22-0A qq
Acionamento em corrente continua4 – 3TH30 40-0B qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 117 35 60 4,83 1 3TH30 31-0B qq2 2 3TH30 22-0B qq
Execuções de contatos Contatores Proteção contra Seção dos condutores Dimensões (mm)auxiliares curto-circuíto
(Icc ≤ 1kA)Para completar Fusível máximo Fio Cabo flexível o tipo qq (tensão DIAZED, com terminale frequência) veja NEOZED ou NH tubulartabela abaixo Minidisjuntor
� Bloco
5SX (curva C)aditivo
Fixação: rápida por engate em trilho ou(A) (mm2) (mm2) por parafusos. Trilho de 3,5 x 7,5 mm
a h p x y dØ
Combinações de blocos aditivos com contatores
Minicontatores auxiliares
3TH20 40-0A qq 4NA 3TH20 31-0A qq 3NA + 1NF 3TH20 22-0A qq 2NA + 2NF3TH20 40-0B qq 4NA 3TH20 31-0B qq 3NA + 1NF 3TH20 22-0B qq 2NA + 2NF
Blocos aditivos
( 4 contatos ) ( 2 contatos ) ( 4 contatos ) ( 2 contatos ) ( 4 contatos ) ( 2 contatos )
Combinações8NA 6NA 7NA + 1NF 5NA + 1NF 6NA + 2NF 4NA + 2NF7NA + 1NF 4NA + 2NF 6NA + 2NF 3NA + 3NF 5NA + 3NF 2NA + 4NF6NA + 2NF 4NA e 5NA + 3NF 3NA + 1NF e 4NA + 4NF 2NA + 2NF e
1NA + 1NF (prolongado) 1NA + 1NF (prolongado) 1NA + 1NF (prolongado)
Bobina 1) Bobina 1)
Contator Tipo Contator Tipo
Execuções de contatos Bloco aditivo Proteção contra Seção dos condutoresde contatos curto-circuíto
(Icc ≤ 1kA)(veja combinações Fusível máximo Fio Cabo flexívelcom contatores DIAZED, com terminalabaixo) NEOZED ou NH tubular
(A) (mm2) (mm2)
4 – – – 3TX4 440-2A 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5)2 – – – 3TX4 420-2A– 2 – – 3TX4 402-2A3 1 – – 3TX4 431-2A2 2 – – 3TX4 422-2A– – 1 1 3TX4 411-2G
Tabela de escolha
Minicontatores auxiliares 3TH20Para bloco aditivo de contatos
Tabela de escolha
Contatores auxiliares 3TH3Para blocos aditivos de contatos
Tabela de escolha
Contatores auxiliares 3TH4
Peça de reposição
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Acessórios
Execuções de contatos Minicontatores Proteção contra Seção dos condutores Dimensões (mm)auxiliares curto-circuíto
(Icc ≤ 1kA)Para completar Fusível máximo Fio Cabo flexível o tipo qq (tensão DIAZED, com terminale frequência) veja NEOZED ou NH tubulartabela abaixo
� Bloco aditivo � Supressor
Fixação: rápida por engate em trilho ou(A) (mm2) (mm2) por parafusos. Trilho de 3,5 x 7,5 mm
a h p x y dØ
Tabela para complementar o tipo qq
Acionamento em corrente alternada Acionamento em corrente contínua24 V/60 Hz - C1 110 V/60 Hz - G1 127 V/60 Hz - F0 220 V/60 Hz - N1 24 V - B4 48 V - W4 110 V - F4 125 V - G4
Tabela para completar o tipo qqAcionamento em corrente alternada Acionamento em corrente contínua24 V/60 Hz - C1 110 V/60 Hz - G1 220 V/60 Hz - N1 240 V/60 Hz - P1 12 V - A4 48 V - W4 125 V - G424 V/50 Hz - B0 110 V/50 Hz - F0 220 V/50 Hz - M0 380 V/60 Hz - Q1 24 V - B4 110 V - F4 220 V - M442 V/60 Hz - G0 115 V/60 Hz - K1 220 V/50-60 Hz - N2 380 V/50 Hz - Q042 V/50 Hz - D6 120 V/60 Hz - K1 230 V/50 Hz - M0 440 V/60 Hz - Q048 V/60 Hz - D6 127 V/60 Hz - F0 230 V/60 Hz - P1
Tabela para completar o tipo qq
Para 3TH40, 3TH42, 3TH43
Acionamento em corrente alternada24 V/60 Hz - C1 110 V/60 Hz - G1 220 V/60 Hz - N1 240 V/60 Hz - P1
24 V/50 Hz - B0 110 V/50 Hz - F0 220 V/50 Hz - M0 380 V/60 Hz - Q1
42 V/60 Hz - G0 115 V/60 Hz - K1 220 V/50-60 Hz - N2 380 V/50 Hz - Q0
42 V/50 Hz - D6 120 V/60 Hz - K1 230 V/50 Hz - M0 440 V/60 Hz - Q0
48 V/60 Hz - D6 127 V/60 Hz - F0 230 V/60 Hz - P1
Para 3TH42
Acionamento em corrente contínua12 V - A4 24 V - B4 48 V - W4 110 V - F4 125 V - G4 220 V - M4
Para 3TH44 54
Acionamento em corrente alternada110 V/50-60 Hz - G2 220 V/50-60 Hz - N2
1) Tabela para complementar o tipo qqAcionamento em corrente alternada24 V/60 Hz - C1 48 V/60 Hz - D6 115 V/60 Hz - K1 220 V/50 Hz - M0 240 V/60 Hz - P124 V/50 Hz - B0 110 V/60 Hz - G1 120 V/60 Hz - K1 220 V/50-60 Hz - N2 380 V/60 Hz - Q142 V/60 Hz - G0 110 V/50 Hz - F0 127 V/60 Hz - F0 230 V/50 Hz - M0 380 V/50 Hz - Q042 V/50 Hz - D6 110 V/50-60 Hz - G2 220 V/60 Hz - N1 230 V/60 Hz - P1 440 V/60 Hz - Q0Acionamento em corrente contínua12 V - A4 24 V - B4 48 V - W4 110 V - F4 125 V - G4 220 V - M4
Acionamento em corrente alternada Acionamento em corrente contínua
3TH30, 3TH40, 3TH42, 3TY7 403-0A qq 3TH30, 3TH42 3TY4 803-0B qq3TH43, 3TH44
2) Diodo 3) Ligado em série com a bobina do contator, temporiza (atrasa) a sua ligação. Acresce a profundidade do contator ( 3TH20 ) 28 mm (veja na Tabela de escolha ao lado)4) Acresce a profundidade do contator ( 3TH30 ) 63 mm (veja Tabela de escolha ao lado)5) Acresce a profundidade do contator ( 3TH30 ) 90 mm (veja Tabela de escolha ao lado)
NA NF NA NFa
x
dø yh
p 28 25
21
h
pa
y
dø
3110
x
1
ax
hy
dø
p
NA NF NA NFprolongado
NA NF NA NFprolongado
1) Minidisjuntor 5SX
Supressor de sobretensão
Acoplável ao contator Tensão de comando TipoExecuçãoVaristor RC
3TH20 24 a 48 VCA e 24 a 70 VCC 3TX4 490-3G 3TX4 490-3R48 a 127 VCA e 70 a 150 VCC 3TX4 490-3H 3TX4 490-3S127 a 240 VCA e 150 a 250 VCC 3TX4 490-3J 3TX4 490-3T24 a 250 VCC 3TX4 490-3A 2) –
3TH30, 3TH40, 3TH42, 24 a 48 VCA e 24 a 70 VCC 3TX7 402-3G 3TX7 402-3R3TH43, 3TH44 48 a 127 VCA e 70 a 150 VCC 3TX7 402-3H 3TX7 402-3S
127 a 240 VCA e 150 a 250 VCC 3TX7 402-3J 3TX7 402-3T240 a 400 VCA 3TX7 402-3K 3TX7 402-3V400 a 600 VCA 3TX7 402-3L 3TX7 402-3U
Bloco aditivo temporizado eletrônico 3)
Acoplável ao contator Função Ajuste de Tensão de Tipotempo comando
3TH20 Retardo na 1,5 a 30 s 90 a 250 VCA / CC 7PX73 40-2CM30ligação
Bloco aditivo temporizado pneumático 4)
Acoplável ao contator Função Ajuste de Contatos Tipotempo auxiliares
3TH30 Retardo na 0,1 a 30 s 1NA + 1NF 3TX4 092-0Aligação
Retardo no 3TX4 092-5Adesligamento
Bloco aditivo de travamento mecânico (memória) 5)
Acoplável ao contator Tensão de comando Tipo
3TH30 24 VCA / CC 3TX4 090-0GB3110 VCA / CC 3TX4 090-0GF3230 VCA / CC 3TX4 090-0GP3
NA NF NA NFprolongado
Execuções de contatos Bloco aditivo Proteção contra Seção dos condutoresde contatos curto-circuíto
(Icc ≤ 1kA)(veja combinações Fusível máximo Fio Cabo flexívelcom contatores DIAZED, com terminalabaixo) NEOZED ou NH tubular
Minidisjuntor5SX (curva C)(A) (mm2) (mm2)
1 – – – 3TX4 010-2A 16 / 10 1) 2 x (0,5 - 2,5) 2 x (0,75 - 2,5)– 1 – – 3TX4 001-2A– – 1 – 3TX4 010-4A– – – 1 3TX4 001-4A1 – – – 3TX4 010-3A
(com indicador de estado ligado desligado
Acionamento em corrente alternada4 – 3TH20 40-0A qq 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5) 45 48 68 35 40 4,43 1 3TH20 31-0A qq2 2 3TH20 22-0A qq
Acionamento em corrente contínua4 – 3TH20 40-0B qq 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5) 45 48 68 35 40 4,43 1 3TH20 31-0B qq2 2 3TH20 22-0B qq
Para interface com eletrônica industrial 1). Acionamento em corrente contínua 24 VCC. 4 – 3TH20 40-0FB4 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5) 45 48 68 35 40 4,43 1 3TH20 31-0FB42 2 3TH20 22-0FB4
1) Contatores para interface não permitem uso de bloco aditivo
Combinações de blocos aditivos com contatoresContatores auxiliares
3TH30 40-0A qq 4NA 3TH30 31-0A qq 3NA + 1NF 3TH30 22-0A qq 2NA + 2NF3TH30 40-0B qq 4NA 3TH30 31-0B qq 3NA + 1NF 3TH30 22-0B qq 2NA + 2NF
Blocos aditivos (Pode-se montar até quatro blocos aditivos. Atendendo as normas, os números de identificação dos contatos estão inscritos respectivamente, o de posição nocontator e o de função no bloco aditivo).
Combinações5NA 6NA 7NA 8NA 4NA + 1NF 5NA + 1NF 6NA + 1NF 7NA + 1NF 3NA + 2NF 4NA + 2NF 5NA + 2NF 6NA + 2NF4NA + 1NF 5NA + 1NF 6NA + 1NF 7NA + 1NF 4NA + 2NF 5NA + 2NF 6NA + 2NF 2NA + 3NF 3NA + 3NF 4NA + 3NF 5NA + 3NF
4NA + 2NF 5NA + 2NF 6NA + 2NF 4NA + 3NF 5NA + 3NF 2NA + 4NF 3NA + 4NF 4NA + 4NF4NA + 3NF 5NA + 3NF
4NA + 4NF
Acionamento em corrente alternada4 – – – 3TH40 40-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 86 35 60 4,83 1 – – 3TH40 31-0A qq
2 2 – – 3TH40 22-0A qq
1 3 – – 3TH40 13-0A qq
– 4 – – 3TH40 04-0A qq
8 – – – 3TH42 80-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 112 35 60 4,87 1 – – 3TH42 71-0A qq
6 2 – – 3TH42 62-0A qq
5 3 – – 3TH42 53-0A qq
4 4 – – 3TH42 44-0A qq
3 3 1 1 3TH42 93-0A qq
10 – – – 3TH43 10-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 55 78 112 35 60 4,89 1 – – 3TH43 91-0A qq
8 2 – – 3TH43 82-0A qq
7 3 – – 3TH43 73-0A qq
6 4 – – 3TH43 64-0A qq
5 5 – – 3TH43 55-0A qq
6 2 1 1 3TH43 46-0A qq
4 4 1 1 3TH43 94-0A qq
Acionamento em corrente continua
8 – – – 3TH42 80-0B qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 135 35 60 4,87 1 – – 3TH42 71-0B qq
6 2 – – 3TH42 62-0B qq
5 3 – – 3TH42 53-0B qq
4 4 – – 3TH42 44-0B qq
3 3 1 1 3TH42 93-0B qq
Com bloqueio mecânico (memória). Acionamento em corrente alternada
5 4 – – 3TH44 54-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 55 78 140 35 60 4,8
Execuções de contatos Contatores Proteção contra Seção dos condutores Dimensões (mm)auxiliares curto-circuíto
(Icc ≤ 1kA)Para completar Fusível máximo Fio Cabo flexível o tipo qq (tensão DIAZED, com terminale frequência) veja NEOZED ou NH tubulartabela abaixo Minidisjuntor
5SX (curva C)Fixação: rápida por engate em trilho ou
(A) (mm2) (mm2) por parafusos. Trilho de 3,5 x 7,5 mma h p x y dØ
Acionamento em corrente alternada4 – 3TH30 40-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 85 35 60 4,83 1 3TH30 31-0A qq2 2 3TH30 22-0A qq
Acionamento em corrente continua4 – 3TH30 40-0B qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 117 35 60 4,83 1 3TH30 31-0B qq2 2 3TH30 22-0B qq
Execuções de contatos Contatores Proteção contra Seção dos condutores Dimensões (mm)auxiliares curto-circuíto
(Icc ≤ 1kA)Para completar Fusível máximo Fio Cabo flexível o tipo qq (tensão DIAZED, com terminale frequência) veja NEOZED ou NH tubulartabela abaixo Minidisjuntor
� Bloco
5SX (curva C)aditivo
Fixação: rápida por engate em trilho ou(A) (mm2) (mm2) por parafusos. Trilho de 3,5 x 7,5 mm
a h p x y dØ
Combinações de blocos aditivos com contatores
Minicontatores auxiliares
3TH20 40-0A qq 4NA 3TH20 31-0A qq 3NA + 1NF 3TH20 22-0A qq 2NA + 2NF3TH20 40-0B qq 4NA 3TH20 31-0B qq 3NA + 1NF 3TH20 22-0B qq 2NA + 2NF
Blocos aditivos
( 4 contatos ) ( 2 contatos ) ( 4 contatos ) ( 2 contatos ) ( 4 contatos ) ( 2 contatos )
Combinações8NA 6NA 7NA + 1NF 5NA + 1NF 6NA + 2NF 4NA + 2NF7NA + 1NF 4NA + 2NF 6NA + 2NF 3NA + 3NF 5NA + 3NF 2NA + 4NF6NA + 2NF 4NA e 5NA + 3NF 3NA + 1NF e 4NA + 4NF 2NA + 2NF e
1NA + 1NF (prolongado) 1NA + 1NF (prolongado) 1NA + 1NF (prolongado)
Bobina 1) Bobina 1)
Contator Tipo Contator Tipo
Execuções de contatos Bloco aditivo Proteção contra Seção dos condutoresde contatos curto-circuíto
(Icc ≤ 1kA)(veja combinações Fusível máximo Fio Cabo flexívelcom contatores DIAZED, com terminalabaixo) NEOZED ou NH tubular
(A) (mm2) (mm2)
4 – – – 3TX4 440-2A 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5)2 – – – 3TX4 420-2A– 2 – – 3TX4 402-2A3 1 – – 3TX4 431-2A2 2 – – 3TX4 422-2A– – 1 1 3TX4 411-2G
Tabela de escolha
Minicontatores auxiliares 3TH20Para bloco aditivo de contatos
Tabela de escolha
Contatores auxiliares 3TH3Para blocos aditivos de contatos
Tabela de escolha
Contatores auxiliares 3TH4
Peça de reposição
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Acessórios
Execuções de contatos Minicontatores Proteção contra Seção dos condutores Dimensões (mm)auxiliares curto-circuíto
(Icc ≤ 1kA)Para completar Fusível máximo Fio Cabo flexível o tipo qq (tensão DIAZED, com terminale frequência) veja NEOZED ou NH tubulartabela abaixo
� Bloco aditivo � Supressor
Fixação: rápida por engate em trilho ou(A) (mm2) (mm2) por parafusos. Trilho de 3,5 x 7,5 mm
a h p x y dØ
Tabela para complementar o tipo qq
Acionamento em corrente alternada Acionamento em corrente contínua24 V/60 Hz - C1 110 V/60 Hz - G1 127 V/60 Hz - F0 220 V/60 Hz - N1 24 V - B4 48 V - W4 110 V - F4 125 V - G4
Tabela para completar o tipo qqAcionamento em corrente alternada Acionamento em corrente contínua24 V/60 Hz - C1 110 V/60 Hz - G1 220 V/60 Hz - N1 240 V/60 Hz - P1 12 V - A4 48 V - W4 125 V - G424 V/50 Hz - B0 110 V/50 Hz - F0 220 V/50 Hz - M0 380 V/60 Hz - Q1 24 V - B4 110 V - F4 220 V - M442 V/60 Hz - G0 115 V/60 Hz - K1 220 V/50-60 Hz - N2 380 V/50 Hz - Q042 V/50 Hz - D6 120 V/60 Hz - K1 230 V/50 Hz - M0 440 V/60 Hz - Q048 V/60 Hz - D6 127 V/60 Hz - F0 230 V/60 Hz - P1
Tabela para completar o tipo qq
Para 3TH40, 3TH42, 3TH43
Acionamento em corrente alternada24 V/60 Hz - C1 110 V/60 Hz - G1 220 V/60 Hz - N1 240 V/60 Hz - P1
24 V/50 Hz - B0 110 V/50 Hz - F0 220 V/50 Hz - M0 380 V/60 Hz - Q1
42 V/60 Hz - G0 115 V/60 Hz - K1 220 V/50-60 Hz - N2 380 V/50 Hz - Q0
42 V/50 Hz - D6 120 V/60 Hz - K1 230 V/50 Hz - M0 440 V/60 Hz - Q0
48 V/60 Hz - D6 127 V/60 Hz - F0 230 V/60 Hz - P1
Para 3TH42
Acionamento em corrente contínua12 V - A4 24 V - B4 48 V - W4 110 V - F4 125 V - G4 220 V - M4
Para 3TH44 54
Acionamento em corrente alternada110 V/50-60 Hz - G2 220 V/50-60 Hz - N2
1) Tabela para complementar o tipo qqAcionamento em corrente alternada24 V/60 Hz - C1 48 V/60 Hz - D6 115 V/60 Hz - K1 220 V/50 Hz - M0 240 V/60 Hz - P124 V/50 Hz - B0 110 V/60 Hz - G1 120 V/60 Hz - K1 220 V/50-60 Hz - N2 380 V/60 Hz - Q142 V/60 Hz - G0 110 V/50 Hz - F0 127 V/60 Hz - F0 230 V/50 Hz - M0 380 V/50 Hz - Q042 V/50 Hz - D6 110 V/50-60 Hz - G2 220 V/60 Hz - N1 230 V/60 Hz - P1 440 V/60 Hz - Q0Acionamento em corrente contínua12 V - A4 24 V - B4 48 V - W4 110 V - F4 125 V - G4 220 V - M4
Acionamento em corrente alternada Acionamento em corrente contínua
3TH30, 3TH40, 3TH42, 3TY7 403-0A qq 3TH30, 3TH42 3TY4 803-0B qq3TH43, 3TH44
2) Diodo 3) Ligado em série com a bobina do contator, temporiza (atrasa) a sua ligação. Acresce a profundidade do contator ( 3TH20 ) 28 mm (veja na Tabela de escolha ao lado)4) Acresce a profundidade do contator ( 3TH30 ) 63 mm (veja Tabela de escolha ao lado)5) Acresce a profundidade do contator ( 3TH30 ) 90 mm (veja Tabela de escolha ao lado)
NA NF NA NFa
x
dø yh
p 28 25
21
h
pa
y
dø
3110
x
1
ax
hy
dø
p
NA NF NA NFprolongado
NA NF NA NFprolongado
1) Minidisjuntor 5SX
Supressor de sobretensão
Acoplável ao contator Tensão de comando TipoExecuçãoVaristor RC
3TH20 24 a 48 VCA e 24 a 70 VCC 3TX4 490-3G 3TX4 490-3R48 a 127 VCA e 70 a 150 VCC 3TX4 490-3H 3TX4 490-3S127 a 240 VCA e 150 a 250 VCC 3TX4 490-3J 3TX4 490-3T24 a 250 VCC 3TX4 490-3A 2) –
3TH30, 3TH40, 3TH42, 24 a 48 VCA e 24 a 70 VCC 3TX7 402-3G 3TX7 402-3R3TH43, 3TH44 48 a 127 VCA e 70 a 150 VCC 3TX7 402-3H 3TX7 402-3S
127 a 240 VCA e 150 a 250 VCC 3TX7 402-3J 3TX7 402-3T240 a 400 VCA 3TX7 402-3K 3TX7 402-3V400 a 600 VCA 3TX7 402-3L 3TX7 402-3U
Bloco aditivo temporizado eletrônico 3)
Acoplável ao contator Função Ajuste de Tensão de Tipotempo comando
3TH20 Retardo na 1,5 a 30 s 90 a 250 VCA / CC 7PX73 40-2CM30ligação
Bloco aditivo temporizado pneumático 4)
Acoplável ao contator Função Ajuste de Contatos Tipotempo auxiliares
3TH30 Retardo na 0,1 a 30 s 1NA + 1NF 3TX4 092-0Aligação
Retardo no 3TX4 092-5Adesligamento
Bloco aditivo de travamento mecânico (memória) 5)
Acoplável ao contator Tensão de comando Tipo
3TH30 24 VCA / CC 3TX4 090-0GB3110 VCA / CC 3TX4 090-0GF3230 VCA / CC 3TX4 090-0GP3
NA NF NA NFprolongado
Execuções de contatos Bloco aditivo Proteção contra Seção dos condutoresde contatos curto-circuíto
(Icc ≤ 1kA)(veja combinações Fusível máximo Fio Cabo flexívelcom contatores DIAZED, com terminalabaixo) NEOZED ou NH tubular
Minidisjuntor5SX (curva C)(A) (mm2) (mm2)
1 – – – 3TX4 010-2A 16 / 10 1) 2 x (0,5 - 2,5) 2 x (0,75 - 2,5)– 1 – – 3TX4 001-2A– – 1 – 3TX4 010-4A– – – 1 3TX4 001-4A1 – – – 3TX4 010-3A
(com indicador de estado ligado desligado
Acionamento em corrente alternada4 – 3TH20 40-0A qq 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5) 45 48 68 35 40 4,43 1 3TH20 31-0A qq2 2 3TH20 22-0A qq
Acionamento em corrente contínua4 – 3TH20 40-0B qq 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5) 45 48 68 35 40 4,43 1 3TH20 31-0B qq2 2 3TH20 22-0B qq
Para interface com eletrônica industrial 1). Acionamento em corrente contínua 24 VCC. 4 – 3TH20 40-0FB4 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5) 45 48 68 35 40 4,43 1 3TH20 31-0FB42 2 3TH20 22-0FB4
1) Contatores para interface não permitem uso de bloco aditivo
Combinações de blocos aditivos com contatoresContatores auxiliares
3TH30 40-0A qq 4NA 3TH30 31-0A qq 3NA + 1NF 3TH30 22-0A qq 2NA + 2NF3TH30 40-0B qq 4NA 3TH30 31-0B qq 3NA + 1NF 3TH30 22-0B qq 2NA + 2NF
Blocos aditivos (Pode-se montar até quatro blocos aditivos. Atendendo as normas, os números de identificação dos contatos estão inscritos respectivamente, o de posição nocontator e o de função no bloco aditivo).
Combinações5NA 6NA 7NA 8NA 4NA + 1NF 5NA + 1NF 6NA + 1NF 7NA + 1NF 3NA + 2NF 4NA + 2NF 5NA + 2NF 6NA + 2NF4NA + 1NF 5NA + 1NF 6NA + 1NF 7NA + 1NF 4NA + 2NF 5NA + 2NF 6NA + 2NF 2NA + 3NF 3NA + 3NF 4NA + 3NF 5NA + 3NF
4NA + 2NF 5NA + 2NF 6NA + 2NF 4NA + 3NF 5NA + 3NF 2NA + 4NF 3NA + 4NF 4NA + 4NF4NA + 3NF 5NA + 3NF
4NA + 4NF
Acionamento em corrente alternada4 – – – 3TH40 40-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 86 35 60 4,83 1 – – 3TH40 31-0A qq
2 2 – – 3TH40 22-0A qq
1 3 – – 3TH40 13-0A qq
– 4 – – 3TH40 04-0A qq
8 – – – 3TH42 80-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 112 35 60 4,87 1 – – 3TH42 71-0A qq
6 2 – – 3TH42 62-0A qq
5 3 – – 3TH42 53-0A qq
4 4 – – 3TH42 44-0A qq
3 3 1 1 3TH42 93-0A qq
10 – – – 3TH43 10-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 55 78 112 35 60 4,89 1 – – 3TH43 91-0A qq
8 2 – – 3TH43 82-0A qq
7 3 – – 3TH43 73-0A qq
6 4 – – 3TH43 64-0A qq
5 5 – – 3TH43 55-0A qq
6 2 1 1 3TH43 46-0A qq
4 4 1 1 3TH43 94-0A qq
Acionamento em corrente continua
8 – – – 3TH42 80-0B qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 135 35 60 4,87 1 – – 3TH42 71-0B qq
6 2 – – 3TH42 62-0B qq
5 3 – – 3TH42 53-0B qq
4 4 – – 3TH42 44-0B qq
3 3 1 1 3TH42 93-0B qq
Com bloqueio mecânico (memória). Acionamento em corrente alternada
5 4 – – 3TH44 54-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 55 78 140 35 60 4,8
Execuções de contatos Contatores Proteção contra Seção dos condutores Dimensões (mm)auxiliares curto-circuíto
(Icc ≤ 1kA)Para completar Fusível máximo Fio Cabo flexível o tipo qq (tensão DIAZED, com terminale frequência) veja NEOZED ou NH tubulartabela abaixo Minidisjuntor
5SX (curva C)Fixação: rápida por engate em trilho ou
(A) (mm2) (mm2) por parafusos. Trilho de 3,5 x 7,5 mma h p x y dØ
Acionamento em corrente alternada4 – 3TH30 40-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 85 35 60 4,83 1 3TH30 31-0A qq2 2 3TH30 22-0A qq
Acionamento em corrente continua4 – 3TH30 40-0B qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 117 35 60 4,83 1 3TH30 31-0B qq2 2 3TH30 22-0B qq
Execuções de contatos Contatores Proteção contra Seção dos condutores Dimensões (mm)auxiliares curto-circuíto
(Icc ≤ 1kA)Para completar Fusível máximo Fio Cabo flexível o tipo qq (tensão DIAZED, com terminale frequência) veja NEOZED ou NH tubulartabela abaixo Minidisjuntor
� Bloco
5SX (curva C)aditivo
Fixação: rápida por engate em trilho ou(A) (mm2) (mm2) por parafusos. Trilho de 3,5 x 7,5 mm
a h p x y dØ
Combinações de blocos aditivos com contatores
Minicontatores auxiliares
3TH20 40-0A qq 4NA 3TH20 31-0A qq 3NA + 1NF 3TH20 22-0A qq 2NA + 2NF3TH20 40-0B qq 4NA 3TH20 31-0B qq 3NA + 1NF 3TH20 22-0B qq 2NA + 2NF
Blocos aditivos
( 4 contatos ) ( 2 contatos ) ( 4 contatos ) ( 2 contatos ) ( 4 contatos ) ( 2 contatos )
Combinações8NA 6NA 7NA + 1NF 5NA + 1NF 6NA + 2NF 4NA + 2NF7NA + 1NF 4NA + 2NF 6NA + 2NF 3NA + 3NF 5NA + 3NF 2NA + 4NF6NA + 2NF 4NA e 5NA + 3NF 3NA + 1NF e 4NA + 4NF 2NA + 2NF e
1NA + 1NF (prolongado) 1NA + 1NF (prolongado) 1NA + 1NF (prolongado)
Bobina 1) Bobina 1)
Contator Tipo Contator Tipo
Execuções de contatos Bloco aditivo Proteção contra Seção dos condutoresde contatos curto-circuíto
(Icc ≤ 1kA)(veja combinações Fusível máximo Fio Cabo flexívelcom contatores DIAZED, com terminalabaixo) NEOZED ou NH tubular
(A) (mm2) (mm2)
4 – – – 3TX4 440-2A 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5)2 – – – 3TX4 420-2A– 2 – – 3TX4 402-2A3 1 – – 3TX4 431-2A2 2 – – 3TX4 422-2A– – 1 1 3TX4 411-2G
Tabela de escolha
Minicontatores auxiliares 3TH20Para bloco aditivo de contatos
Tabela de escolha
Contatores auxiliares 3TH3Para blocos aditivos de contatos
Tabela de escolha
Contatores auxiliares 3TH4
Peça de reposição
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Acessórios
Execuções de contatos Minicontatores Proteção contra Seção dos condutores Dimensões (mm)auxiliares curto-circuíto
(Icc ≤ 1kA)Para completar Fusível máximo Fio Cabo flexível o tipo qq (tensão DIAZED, com terminale frequência) veja NEOZED ou NH tubulartabela abaixo
� Bloco aditivo � Supressor
Fixação: rápida por engate em trilho ou(A) (mm2) (mm2) por parafusos. Trilho de 3,5 x 7,5 mm
a h p x y dØ
Tabela para complementar o tipo qq
Acionamento em corrente alternada Acionamento em corrente contínua24 V/60 Hz - C1 110 V/60 Hz - G1 127 V/60 Hz - F0 220 V/60 Hz - N1 24 V - B4 48 V - W4 110 V - F4 125 V - G4
Tabela para completar o tipo qqAcionamento em corrente alternada Acionamento em corrente contínua24 V/60 Hz - C1 110 V/60 Hz - G1 220 V/60 Hz - N1 240 V/60 Hz - P1 12 V - A4 48 V - W4 125 V - G424 V/50 Hz - B0 110 V/50 Hz - F0 220 V/50 Hz - M0 380 V/60 Hz - Q1 24 V - B4 110 V - F4 220 V - M442 V/60 Hz - G0 115 V/60 Hz - K1 220 V/50-60 Hz - N2 380 V/50 Hz - Q042 V/50 Hz - D6 120 V/60 Hz - K1 230 V/50 Hz - M0 440 V/60 Hz - Q048 V/60 Hz - D6 127 V/60 Hz - F0 230 V/60 Hz - P1
Tabela para completar o tipo qq
Para 3TH40, 3TH42, 3TH43
Acionamento em corrente alternada24 V/60 Hz - C1 110 V/60 Hz - G1 220 V/60 Hz - N1 240 V/60 Hz - P1
24 V/50 Hz - B0 110 V/50 Hz - F0 220 V/50 Hz - M0 380 V/60 Hz - Q1
42 V/60 Hz - G0 115 V/60 Hz - K1 220 V/50-60 Hz - N2 380 V/50 Hz - Q0
42 V/50 Hz - D6 120 V/60 Hz - K1 230 V/50 Hz - M0 440 V/60 Hz - Q0
48 V/60 Hz - D6 127 V/60 Hz - F0 230 V/60 Hz - P1
Para 3TH42
Acionamento em corrente contínua12 V - A4 24 V - B4 48 V - W4 110 V - F4 125 V - G4 220 V - M4
Para 3TH44 54
Acionamento em corrente alternada110 V/50-60 Hz - G2 220 V/50-60 Hz - N2
1) Tabela para complementar o tipo qqAcionamento em corrente alternada24 V/60 Hz - C1 48 V/60 Hz - D6 115 V/60 Hz - K1 220 V/50 Hz - M0 240 V/60 Hz - P124 V/50 Hz - B0 110 V/60 Hz - G1 120 V/60 Hz - K1 220 V/50-60 Hz - N2 380 V/60 Hz - Q142 V/60 Hz - G0 110 V/50 Hz - F0 127 V/60 Hz - F0 230 V/50 Hz - M0 380 V/50 Hz - Q042 V/50 Hz - D6 110 V/50-60 Hz - G2 220 V/60 Hz - N1 230 V/60 Hz - P1 440 V/60 Hz - Q0Acionamento em corrente contínua12 V - A4 24 V - B4 48 V - W4 110 V - F4 125 V - G4 220 V - M4
Acionamento em corrente alternada Acionamento em corrente contínua
3TH30, 3TH40, 3TH42, 3TY7 403-0A qq 3TH30, 3TH42 3TY4 803-0B qq3TH43, 3TH44
2) Diodo 3) Ligado em série com a bobina do contator, temporiza (atrasa) a sua ligação. Acresce a profundidade do contator ( 3TH20 ) 28 mm (veja na Tabela de escolha ao lado)4) Acresce a profundidade do contator ( 3TH30 ) 63 mm (veja Tabela de escolha ao lado)5) Acresce a profundidade do contator ( 3TH30 ) 90 mm (veja Tabela de escolha ao lado)
NA NF NA NFa
x
dø yh
p 28 25
21
h
pa
y
dø
3110
x
1
ax
hy
dø
p
NA NF NA NFprolongado
NA NF NA NFprolongado
1) Minidisjuntor 5SX
Supressor de sobretensão
Acoplável ao contator Tensão de comando TipoExecuçãoVaristor RC
3TH20 24 a 48 VCA e 24 a 70 VCC 3TX4 490-3G 3TX4 490-3R48 a 127 VCA e 70 a 150 VCC 3TX4 490-3H 3TX4 490-3S127 a 240 VCA e 150 a 250 VCC 3TX4 490-3J 3TX4 490-3T24 a 250 VCC 3TX4 490-3A 2) –
3TH30, 3TH40, 3TH42, 24 a 48 VCA e 24 a 70 VCC 3TX7 402-3G 3TX7 402-3R3TH43, 3TH44 48 a 127 VCA e 70 a 150 VCC 3TX7 402-3H 3TX7 402-3S
127 a 240 VCA e 150 a 250 VCC 3TX7 402-3J 3TX7 402-3T240 a 400 VCA 3TX7 402-3K 3TX7 402-3V400 a 600 VCA 3TX7 402-3L 3TX7 402-3U
Bloco aditivo temporizado eletrônico 3)
Acoplável ao contator Função Ajuste de Tensão de Tipotempo comando
3TH20 Retardo na 1,5 a 30 s 90 a 250 VCA / CC 7PX73 40-2CM30ligação
Bloco aditivo temporizado pneumático 4)
Acoplável ao contator Função Ajuste de Contatos Tipotempo auxiliares
3TH30 Retardo na 0,1 a 30 s 1NA + 1NF 3TX4 092-0Aligação
Retardo no 3TX4 092-5Adesligamento
Bloco aditivo de travamento mecânico (memória) 5)
Acoplável ao contator Tensão de comando Tipo
3TH30 24 VCA / CC 3TX4 090-0GB3110 VCA / CC 3TX4 090-0GF3230 VCA / CC 3TX4 090-0GP3
NA NF NA NFprolongado
Execuções de contatos Bloco aditivo Proteção contra Seção dos condutoresde contatos curto-circuíto
(Icc ≤ 1kA)(veja combinações Fusível máximo Fio Cabo flexívelcom contatores DIAZED, com terminalabaixo) NEOZED ou NH tubular
Minidisjuntor5SX (curva C)(A) (mm2) (mm2)
1 – – – 3TX4 010-2A 16 / 10 1) 2 x (0,5 - 2,5) 2 x (0,75 - 2,5)– 1 – – 3TX4 001-2A– – 1 – 3TX4 010-4A– – – 1 3TX4 001-4A1 – – – 3TX4 010-3A
(com indicador de estado ligado desligado
Acionamento em corrente alternada4 – 3TH20 40-0A qq 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5) 45 48 68 35 40 4,43 1 3TH20 31-0A qq2 2 3TH20 22-0A qq
Acionamento em corrente contínua4 – 3TH20 40-0B qq 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5) 45 48 68 35 40 4,43 1 3TH20 31-0B qq2 2 3TH20 22-0B qq
Para interface com eletrônica industrial 1). Acionamento em corrente contínua 24 VCC. 4 – 3TH20 40-0FB4 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5) 45 48 68 35 40 4,43 1 3TH20 31-0FB42 2 3TH20 22-0FB4
1) Contatores para interface não permitem uso de bloco aditivo
Combinações de blocos aditivos com contatoresContatores auxiliares
3TH30 40-0A qq 4NA 3TH30 31-0A qq 3NA + 1NF 3TH30 22-0A qq 2NA + 2NF3TH30 40-0B qq 4NA 3TH30 31-0B qq 3NA + 1NF 3TH30 22-0B qq 2NA + 2NF
Blocos aditivos (Pode-se montar até quatro blocos aditivos. Atendendo as normas, os números de identificação dos contatos estão inscritos respectivamente, o de posição nocontator e o de função no bloco aditivo).
Combinações5NA 6NA 7NA 8NA 4NA + 1NF 5NA + 1NF 6NA + 1NF 7NA + 1NF 3NA + 2NF 4NA + 2NF 5NA + 2NF 6NA + 2NF4NA + 1NF 5NA + 1NF 6NA + 1NF 7NA + 1NF 4NA + 2NF 5NA + 2NF 6NA + 2NF 2NA + 3NF 3NA + 3NF 4NA + 3NF 5NA + 3NF
4NA + 2NF 5NA + 2NF 6NA + 2NF 4NA + 3NF 5NA + 3NF 2NA + 4NF 3NA + 4NF 4NA + 4NF4NA + 3NF 5NA + 3NF
4NA + 4NF
Acionamento em corrente alternada4 – – – 3TH40 40-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 86 35 60 4,83 1 – – 3TH40 31-0A qq
2 2 – – 3TH40 22-0A qq
1 3 – – 3TH40 13-0A qq
– 4 – – 3TH40 04-0A qq
8 – – – 3TH42 80-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 112 35 60 4,87 1 – – 3TH42 71-0A qq
6 2 – – 3TH42 62-0A qq
5 3 – – 3TH42 53-0A qq
4 4 – – 3TH42 44-0A qq
3 3 1 1 3TH42 93-0A qq
10 – – – 3TH43 10-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 55 78 112 35 60 4,89 1 – – 3TH43 91-0A qq
8 2 – – 3TH43 82-0A qq
7 3 – – 3TH43 73-0A qq
6 4 – – 3TH43 64-0A qq
5 5 – – 3TH43 55-0A qq
6 2 1 1 3TH43 46-0A qq
4 4 1 1 3TH43 94-0A qq
Acionamento em corrente continua
8 – – – 3TH42 80-0B qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 135 35 60 4,87 1 – – 3TH42 71-0B qq
6 2 – – 3TH42 62-0B qq
5 3 – – 3TH42 53-0B qq
4 4 – – 3TH42 44-0B qq
3 3 1 1 3TH42 93-0B qq
Com bloqueio mecânico (memória). Acionamento em corrente alternada
5 4 – – 3TH44 54-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 55 78 140 35 60 4,8
Execuções de contatos Contatores Proteção contra Seção dos condutores Dimensões (mm)auxiliares curto-circuíto
(Icc ≤ 1kA)Para completar Fusível máximo Fio Cabo flexível o tipo qq (tensão DIAZED, com terminale frequência) veja NEOZED ou NH tubulartabela abaixo Minidisjuntor
5SX (curva C)Fixação: rápida por engate em trilho ou
(A) (mm2) (mm2) por parafusos. Trilho de 3,5 x 7,5 mma h p x y dØ
Acionamento em corrente alternada4 – 3TH30 40-0A qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 85 35 60 4,83 1 3TH30 31-0A qq2 2 3TH30 22-0A qq
Acionamento em corrente continua4 – 3TH30 40-0B qq 16 2 x (0,5 - 2,5) 2 x (0,75 - 2,5) 45 78 117 35 60 4,83 1 3TH30 31-0B qq2 2 3TH30 22-0B qq
Execuções de contatos Contatores Proteção contra Seção dos condutores Dimensões (mm)auxiliares curto-circuíto
(Icc ≤ 1kA)Para completar Fusível máximo Fio Cabo flexível o tipo qq (tensão DIAZED, com terminale frequência) veja NEOZED ou NH tubulartabela abaixo Minidisjuntor
� Bloco
5SX (curva C)aditivo
Fixação: rápida por engate em trilho ou(A) (mm2) (mm2) por parafusos. Trilho de 3,5 x 7,5 mm
a h p x y dØ
Combinações de blocos aditivos com contatores
Minicontatores auxiliares
3TH20 40-0A qq 4NA 3TH20 31-0A qq 3NA + 1NF 3TH20 22-0A qq 2NA + 2NF3TH20 40-0B qq 4NA 3TH20 31-0B qq 3NA + 1NF 3TH20 22-0B qq 2NA + 2NF
Blocos aditivos
( 4 contatos ) ( 2 contatos ) ( 4 contatos ) ( 2 contatos ) ( 4 contatos ) ( 2 contatos )
Combinações8NA 6NA 7NA + 1NF 5NA + 1NF 6NA + 2NF 4NA + 2NF7NA + 1NF 4NA + 2NF 6NA + 2NF 3NA + 3NF 5NA + 3NF 2NA + 4NF6NA + 2NF 4NA e 5NA + 3NF 3NA + 1NF e 4NA + 4NF 2NA + 2NF e
1NA + 1NF (prolongado) 1NA + 1NF (prolongado) 1NA + 1NF (prolongado)
Bobina 1) Bobina 1)
Contator Tipo Contator Tipo
Execuções de contatos Bloco aditivo Proteção contra Seção dos condutoresde contatos curto-circuíto
(Icc ≤ 1kA)(veja combinações Fusível máximo Fio Cabo flexívelcom contatores DIAZED, com terminalabaixo) NEOZED ou NH tubular
(A) (mm2) (mm2)
4 – – – 3TX4 440-2A 6 2 x (0,5 - 2,5) 2 x (0,5 - 1,5)2 – – – 3TX4 420-2A– 2 – – 3TX4 402-2A3 1 – – 3TX4 431-2A2 2 – – 3TX4 422-2A– – 1 1 3TX4 411-2G
Tabela de escolha
Minicontatores auxiliares 3TH20Para bloco aditivo de contatos
Tabela de escolha
Contatores auxiliares 3TH3Para blocos aditivos de contatos
Tabela de escolha
Contatores auxiliares 3TH4
Peça de reposição
Minicontatores auxiliares 3TH20Contatores auxiliares 3TH3, 3TH4
Acessórios
Execuções de contatos Minicontatores Proteção contra Seção dos condutores Dimensões (mm)auxiliares curto-circuíto
(Icc ≤ 1kA)Para completar Fusível máximo Fio Cabo flexível o tipo qq (tensão DIAZED, com terminale frequência) veja NEOZED ou NH tubulartabela abaixo
� Bloco aditivo � Supressor
Fixação: rápida por engate em trilho ou(A) (mm2) (mm2) por parafusos. Trilho de 3,5 x 7,5 mm
a h p x y dØ
Tabela para complementar o tipo qq
Acionamento em corrente alternada Acionamento em corrente contínua24 V/60 Hz - C1 110 V/60 Hz - G1 127 V/60 Hz - F0 220 V/60 Hz - N1 24 V - B4 48 V - W4 110 V - F4 125 V - G4
Tabela para completar o tipo qqAcionamento em corrente alternada Acionamento em corrente contínua24 V/60 Hz - C1 110 V/60 Hz - G1 220 V/60 Hz - N1 240 V/60 Hz - P1 12 V - A4 48 V - W4 125 V - G424 V/50 Hz - B0 110 V/50 Hz - F0 220 V/50 Hz - M0 380 V/60 Hz - Q1 24 V - B4 110 V - F4 220 V - M442 V/60 Hz - G0 115 V/60 Hz - K1 220 V/50-60 Hz - N2 380 V/50 Hz - Q042 V/50 Hz - D6 120 V/60 Hz - K1 230 V/50 Hz - M0 440 V/60 Hz - Q048 V/60 Hz - D6 127 V/60 Hz - F0 230 V/60 Hz - P1
Tabela para completar o tipo qq
Para 3TH40, 3TH42, 3TH43
Acionamento em corrente alternada24 V/60 Hz - C1 110 V/60 Hz - G1 220 V/60 Hz - N1 240 V/60 Hz - P1
24 V/50 Hz - B0 110 V/50 Hz - F0 220 V/50 Hz - M0 380 V/60 Hz - Q1
42 V/60 Hz - G0 115 V/60 Hz - K1 220 V/50-60 Hz - N2 380 V/50 Hz - Q0
42 V/50 Hz - D6 120 V/60 Hz - K1 230 V/50 Hz - M0 440 V/60 Hz - Q0
48 V/60 Hz - D6 127 V/60 Hz - F0 230 V/60 Hz - P1
Para 3TH42
Acionamento em corrente contínua12 V - A4 24 V - B4 48 V - W4 110 V - F4 125 V - G4 220 V - M4
Para 3TH44 54
Acionamento em corrente alternada110 V/50-60 Hz - G2 220 V/50-60 Hz - N2
1) Tabela para complementar o tipo qqAcionamento em corrente alternada24 V/60 Hz - C1 48 V/60 Hz - D6 115 V/60 Hz - K1 220 V/50 Hz - M0 240 V/60 Hz - P124 V/50 Hz - B0 110 V/60 Hz - G1 120 V/60 Hz - K1 220 V/50-60 Hz - N2 380 V/60 Hz - Q142 V/60 Hz - G0 110 V/50 Hz - F0 127 V/60 Hz - F0 230 V/50 Hz - M0 380 V/50 Hz - Q042 V/50 Hz - D6 110 V/50-60 Hz - G2 220 V/60 Hz - N1 230 V/60 Hz - P1 440 V/60 Hz - Q0Acionamento em corrente contínua12 V - A4 24 V - B4 48 V - W4 110 V - F4 125 V - G4 220 V - M4
Acionamento em corrente alternada Acionamento em corrente contínua
3TH30, 3TH40, 3TH42, 3TY7 403-0A qq 3TH30, 3TH42 3TY4 803-0B qq3TH43, 3TH44
2) Diodo 3) Ligado em série com a bobina do contator, temporiza (atrasa) a sua ligação. Acresce a profundidade do contator ( 3TH20 ) 28 mm (veja na Tabela de escolha ao lado)4) Acresce a profundidade do contator ( 3TH30 ) 63 mm (veja Tabela de escolha ao lado)5) Acresce a profundidade do contator ( 3TH30 ) 90 mm (veja Tabela de escolha ao lado)
NA NF NA NFa
x
dø yh
p 28 25
21
h
pa
y
dø
3110
x
1
ax
hy
dø
p
NA NF NA NFprolongado
NA NF NA NFprolongado
1) Minidisjuntor 5SX
Supressor de sobretensão
Acoplável ao contator Tensão de comando TipoExecuçãoVaristor RC
3TH20 24 a 48 VCA e 24 a 70 VCC 3TX4 490-3G 3TX4 490-3R48 a 127 VCA e 70 a 150 VCC 3TX4 490-3H 3TX4 490-3S127 a 240 VCA e 150 a 250 VCC 3TX4 490-3J 3TX4 490-3T24 a 250 VCC 3TX4 490-3A 2) –
3TH30, 3TH40, 3TH42, 24 a 48 VCA e 24 a 70 VCC 3TX7 402-3G 3TX7 402-3R3TH43, 3TH44 48 a 127 VCA e 70 a 150 VCC 3TX7 402-3H 3TX7 402-3S
127 a 240 VCA e 150 a 250 VCC 3TX7 402-3J 3TX7 402-3T240 a 400 VCA 3TX7 402-3K 3TX7 402-3V400 a 600 VCA 3TX7 402-3L 3TX7 402-3U
Bloco aditivo temporizado eletrônico 3)
Acoplável ao contator Função Ajuste de Tensão de Tipotempo comando
3TH20 Retardo na 1,5 a 30 s 90 a 250 VCA / CC 7PX73 40-2CM30ligação
Bloco aditivo temporizado pneumático 4)
Acoplável ao contator Função Ajuste de Contatos Tipotempo auxiliares
3TH30 Retardo na 0,1 a 30 s 1NA + 1NF 3TX4 092-0Aligação
Retardo no 3TX4 092-5Adesligamento
Bloco aditivo de travamento mecânico (memória) 5)
Acoplável ao contator Tensão de comando Tipo
3TH30 24 VCA / CC 3TX4 090-0GB3110 VCA / CC 3TX4 090-0GF3230 VCA / CC 3TX4 090-0GP3