Planilha Relatorios de Endl
-
Upload
carlos-alberto-duarte -
Category
Documents
-
view
218 -
download
0
Transcript of Planilha Relatorios de Endl
-
8/3/2019 Planilha Relatorios de Endl
1/2
Data 12/8/2011
Folha 01 / 01
SECA UMIDACOLORIDA FLUORESC
N TIPO COTA COMP LAUDOMR NA NA NA A
A TL FFR TT FP
REC TR MOSP PO
DATA DATA DATA
DESTRUTIVOPARTICULAS MAGNETICAS
2 ) MR - Material Remanescente
OBSERVAES1)END -PM REALIZADO NO MATERIAL REMANESCE DN 24 IN SCH 60 ONDE SERA SOLDADO ADERIVAO DN 16 IN SCH 60 TIE IN 16"-G75-719-Ea-Ni
EQUIPAMENTO/LINHA24"-G75-208-001-Ea-Ni
LOCAL DO EXAMETIE IN DO BY PASS DA U208
TECAB-STM-002/11
CONTRATO7000.OO69168.11.2
CLIENTE: STM Servios Ltda.
RELATORIO DE EXAME NO
PROCEDIMENTO NIDM-PM-02
REVISO N02
NORMAS & CODIGOS DE REFERENCIA
N 115 / N 1598 / ASME B 31.3
CRITERIO DE ACEITAO
ASME Section VIII Div. 1 - APP. 6
VIA PARTICULAS
APARELHO
MAGNA -FLUX Y6
ESPESSURAMETAL DE ADIONA 24,6 mm
METAL DE BASEAPI 5L Gr. B PSL 1
MAGNA FLUX
CONTRASTE
MAGNA FLUX
CROQUIS
CORRENTETECNICA DE MAGNETIZAO
YOKE ELETRODO (PROD) OUTRO
TRINCA LONGITUDINALTRINCA TRANSVERSAL
TRINCA RAMIFICADA
LEGENDAAPROVADO FALTA DE FUSO
Assinat.
FALTA DE PENETR.
MORDEDURASOPREPOSIO POROSIDADE
REPROVADO
REC. END COMP
DMCJ Inspees Ltda. - Rua Vitor Alves ,439 - Campo Grande -RJ - CEP 23.080-180
Tel.: 0 (xx) 21 2413 4459 / 3394 6228 - Email : [email protected] -SITE :www.dmcj.com.br
COORDENADOR DE CQ FISCALIZAOINSPETOR
CC CA
-
8/3/2019 Planilha Relatorios de Endl
2/2