PRÁTICA 1320 CT 1664 COMO VERIFICAR SOFTWARE > CT ENVIRONENT > PROCESS CONTROL VERIFICA SE TODOS OS PROCESSOS ESTÃO VERDE, SE TIVER ALGUM VERMELHO ESTÁ COM FALHA. > LIST SOFTWARE VERIFICA TODOS OS APLICATIVOS EM USO. > MUDAR NSAP (BOTÃO DA DIREITA NO NSAP) > SETTINGS > OTHER SETTINGS (MUDA SIGLA DA ESTAÇÃO) ALARMES DIAGNOSES > ALARMES > NE ALARMES PARA VER ONDE ESTÁ O ALARME CLICA NA LINHA DE ALARME > NAVIGATION > EXTERNAL APLICATION > EML-USM FORÇAR LASER ENTRA NO AGREGADO > CLICA NO BLOCO (IRÁ MOSTRAR A TELA DE VC4, AU4) CLICA NO BLOCO SPI > PORT > PHISICAL MEDIA > ALS MANAGMENT > ALS FUNCTION (FORÇAR EM ON) > APPLY APARECERÁ = LASER CORRENT STATE (FORCED ON) ALS ENABLE BACKUP MIB MANAGEMENT > DIGITA ESTAÇÃO > BACKUP (CLICA CANCEL = OK) COPIAR A MIB PARA UMA PASTA DE DESTINO CRIAR UMA PASTA DENTRO DO DIRETÓRIO “ C “ DO COMPUTADOR COM O NOME DA ESTAÇÃO EX MCL-CEN SELECIONA NE > SUPERVISION > FILES ADMINISTRATION > MIB COPIES > SAVE TO DISK

description

 

Transcript of P RÁ T I C A 1320 C T 1664

Page 1: P RÁ T I C A 1320  C T 1664

PRÁTICA 1320 CT 1664

COMO VERIFICAR SOFTWARE

> CT ENVIRONENT > PROCESS CONTROLVERIFICA SE TODOS OS PROCESSOS ESTÃO VERDE, SE TIVER ALGUM VERMELHO ESTÁ COM FALHA.> LIST SOFTWAREVERIFICA TODOS OS APLICATIVOS EM USO.> MUDAR NSAP (BOTÃO DA DIREITA NO NSAP)> SETTINGS > OTHER SETTINGS (MUDA SIGLA DA ESTAÇÃO)

ALARMESDIAGNOSES > ALARMES > NE ALARMESPARA VER ONDE ESTÁ O ALARME CLICA NA LINHA DE ALARME >NAVIGATION > EXTERNAL APLICATION > EML-USM

FORÇAR LASER

ENTRA NO AGREGADO > CLICA NO BLOCO (IRÁ MOSTRAR A TELA DE VC4, AU4)CLICA NO BLOCO SPI> PORT > PHISICAL MEDIA > ALS MANAGMENT > ALS FUNCTION (FORÇAR EM ON) > APPLYAPARECERÁ = LASER CORRENT STATE (FORCED ON)

ALS ENABLE

BACKUP

MIB MANAGEMENT > DIGITA ESTAÇÃO > BACKUP (CLICA CANCEL = OK)

COPIAR A MIB PARA UMA PASTA DE DESTINO

CRIAR UMA PASTA DENTRO DO DIRETÓRIO “ C “ DO COMPUTADOR COM O NOME DA ESTAÇÃO EX MCL-CENSELECIONA NE > SUPERVISION > FILES ADMINISTRATION > MIB COPIES > SAVE TO DISKCLICA EM FIND NOW > MARCA O ARQUIVO DESJADO > OK (APARECERÁ O DIRETÓRIO)CLICA NA PASTA ONDE SE DESEJA COPIAR > ABRIR (APARECERÁ – THE SELECTED MIB HAS BEEN COPIED TO C: MCL-CEN / B3_5)

Page 2: P RÁ T I C A 1320  C T 1664

TROCAR SMEC

1 2 DIP SWITCH ON OFF POSIÇÃO NORMALOFF ON POSIÇÃO LIMPEZA DE BANCO DE DADOSOFF OFF RECUPERAR LOCAL CONFIGURATION (NE, OS ADRESS,

LAPD, ETHERNET).ON ON RETAURAR O BANCO DE DADOSON OFF POSIÇÃO NORMAL

PASSOS:

PASSO 1 - RETIRAR A SMEC DIP 1 OFF DIP 2 ON – INSERIR A PLACA E AGUARDA OS LED URG E NURG ACENDER. (O BANCO FOI LIMPO).PASSO 2 - RETIRAR A SMEC DIP I OFF DIP 2 ON – INSERIR A PLACA, AGUARDA OS LED URG E NURG ACENDER.(FOI RECUPERADO LOCAL CONFIGURATION).PASSO 3- RETIRAR A SMEC DIP I ON DIP 2 ON – INSERIR A PLACA, AGUARDA OS LED URG E NURG ACENDER.(ENVIAR AS TABELAS DE BACKUP AO NE).PASSO 4 - RETIRAR A SMEC DIP I ON DIP 2 OFF – INSERIR A PLACA, AGUARDA OS LED URG E NURG ACENDER.

RESTORE

SUPERVISION > FILES ADMINISTRATION > MIB COPIES > LOAD FRON DISK > BROUSE > SELECIONA PASTA DA ESTAÇÃO (MCL-CEN) > MARCA O ARQUIVO (B3_5) > OPEN > FIND NOW (MARCA) > OKAPARECE A MENSAGEM (PACKAGE INSTALLED SUCESFULLY)

VERSÃO DA PLACA

DOWNLOAD > UNITS INF (APARECE OS 2 BANCOS DE VERSÃO)SOFTWARE UNITS DETAILS (PERMITE VER DETALHES DAS VERSÕES DE CADA UNIDADE)

INVENTÁRIO

SUB INTEIRO

SUPERVISION > UPLOAD REMOTE INVENTORY > OK ..... AGUARDA!!!

Page 3: P RÁ T I C A 1320  C T 1664

DIAGNOSES > VIW > REMOTE INVENTORY > APARECE ARQUIVO BLOCO DE NOTAS

POR SLOT

SELECIONA O SLOT > REMOT INVENTORY > BOARD LEVEL

CROSS CONEXÃO

CONFIGURATION > CROSS CONECTION MANAGEMENT > SEARCH (VISUALISA AS CROSS EXISTENTES)

INSERIR NA GERÊNCIA

ABRIR NE > SHOW EQUIPMENT > CLICA NO EQUIPAMENTO > CONFIGURATION > COMM / ROUTING > LAPD CONFIGURATION

A) 18 YES LAPD INTERFACE YES USER – LAPD ROLE “ N “ OU “ U “ (DE ACOEDO COM O PROJETO) 17 YES OU NETWORK

B) SÓ PARA GNE´S CONFIGURAR ETHERNET Q3

OBS: GNE É QUANDO SE LIGA A SAÍDA “ Q3 “ NA “ REDE DCN ” E LIGA NO EQUIPAMENTO DE GERÊNCIA.YES – SE COLOCAR EM “ NO ” IRÁ RESETAR A SMECNO – (L2 ONLY)ALARME DE LAPD – CSFSE O PROBLEMA FOR NO Q3, LAN FAILURE OU Q3 FAILURE.

C) OS ADRESS

CONFIGURATION > OS COFIGURATIONNSAP DA GERÊNCIA (13535H)COLOCAR SOMENTE A GERÊNCIA PRINCIPAL (SEGUIR PROJETO)GERÊNCIA SPARE (MENOS USADA)

NSAP39 – FORMATO076F – BRASIL80 – PADRÃO000000 – RESERVADO0000 – OPERADORA0001 – DOMÍNIO0001 – ÁREA002060ABCDEF – SISTEM ID

Page 4: P RÁ T I C A 1320  C T 1664

ID – SELECTOR

D) LOCAL CONFIGURATION > NSAP DO NESYNCRONISMOUS AREA ADRESS OPTICAL (NÃO INSERIR)SISTEM TYPEMARCAR > INTERMEDIATE SYSTEM LY

ACESSO REMOTO

MAP > SAMPLE > NE DIRECTORY > CREATE Q3NEAF1 39IDREPETIR O PROCESSO PARA CADA NE. (SALVAR ATRAVES DO MAPE SAVE)

LIMPAR ALARMES NORMALIZADOS

NA TELA DE ALARMESSELECIONA TODOS > ACTION > ACKNOWLEDGE...

VER ONDE ESTÁ O ALARME

CLICA NO ALARME > NAVIGATION > EXTERNAL APLICATION > EML-USM

HOUSEKIPING

ALARMES EXTERNOS > ENTRA NO AGREGADO > VIWS > EXTERNAL POINTS

CRIAR TELECOMANDO

EXTERNAL POINTS > CONFIGURATION > USER LABEL > NOME DO TELECOMANDO > EXTERNAL STATE OFF (ON ENVIA O TELECOMANDO)

OUTPUT CRITÉRIA > DEFINE DE QUE FORMA SERÁ O TELECOMANDOEX: MANUAL

CRIAR TELESSINA

EXTERNAL POINTS > CONFIGURATION > USER LABEL > NOME DO TELESSINAL > EXTERNAL STATE OFF (ON ENVIA O TELESSINAL)

PARA VISUALIZAR A DESCRIÇÃO DO ALARME NA TELA DE ALARMES

SUBLIST > MODIFY > SELECIONA ADDITIONAL TEST > CLICA NA SETA A DIREITA > APLLY > CLOSE

Page 5: P RÁ T I C A 1320  C T 1664

SINCRONISMO

NATELA DE EQUIPAMENTO

1) CLOCK: EXTERNOIMPUT: 2MHz T3 # AQUALITY: G811PRIORITY: 1

VIEWS > SINCRONIZATION VIW > SELECIONA > SINCRONIZATION > TIMING SOURCE CONFIGURATION > CHOOSE > RACK 1 (ABRIR) > SUBMARCK (ABRIR) > CRU – 6 > 2MHZ T3 # A (MARCA 2MHz T3 # A > OK

OBS: FONTE DE RELÓGIO EXTERNA = GPS

2) CLOCK: RECUPERADOIMPUT: SL....-OPSQUALITY: EXTRATEDPRIORITY: 2

VIEWS > SINCRONIZATION VIW > SELECIONA > SINCRONIZATION > TIMING SOURCE CONFIGURATION > CHOOSE > RACK 1 (ABRIR) > SUBMARCK (ABRIR) >AGG 16 5161 NEW 17 > MARCA OPS > OK > IMPUT QUALITY (EXTRATED) > OK > PRIORITY 2 > OK

3) T0 CONFIG

SINCRONIZATION > T0 CONFIG > MARCA SSM ALGORITHM ENABLING > OK

O SISTEMA ESCOLHE O RELÓGIO PRIMEIRO PELA QUALIDADE, DEPOIS PELA PRIORIDADE.

PARA EXTERIORIZAR RELÓGIO > SINCRONIZATION > T4 CONFIGURATION 811 E 813