UNI EN ISO 9001 : 2008 T&T Sistemi srl Via Leo Valiani 67-77, 52025 Levane-Bucine (AR) Italy Tel.: +39 055 9119101 Fax: +39 055 9119191 Email: [email protected] - Website: www.tetsistemi.com T&T Sistemas Brasil Ltda Rua Lafaiete, 394 – 1° Andar – Sala 5, Centro, CEP 14015-080 Ribeirão Preto – São Paulo - Brasil Tel. +16 3625-5448 - Fax +16 4009-8051 CC Anti-Sourge ANTI-SOURGE CONTROL SYSTEM FOR CENTRIFUGAL COMPRESSOR

Transcript of CC Anti-Sourge - · PDF fileCC Anti-sourge Flexible control system Antisurge Control System...

Page 1: CC Anti-Sourge -  · PDF fileCC Anti-sourge Flexible control system Antisurge Control System is a product that allows to protect your compressor from the sur-ge phenomenon

UNI EN ISO 9001 : 2008SISTEMI

T&T Sistemi srlVia Leo Valiani 67-77, 52025 Levane-Bucine (AR) Italy Tel.: +39 055 9119101 Fax: +39 055 9119191Email: [email protected] - Website: www.tetsistemi.com

T&T Sistemas Brasil LtdaRua Lafaiete, 394 – 1° Andar – Sala 5, Centro, CEP 14015-080 Ribeirão Preto – São Paulo - Brasil Tel. +16 3625-5448 - Fax +16 4009-8051

CC Anti-SourgeANTI-SOURGE CONTROL SYSTEM FOR CENTRIFUGAL COMPRESSOR

Page 2: CC Anti-Sourge -  · PDF fileCC Anti-sourge Flexible control system Antisurge Control System is a product that allows to protect your compressor from the sur-ge phenomenon

UNI EN ISO 9001 : 2008SISTEMI

T&T Sistemi srlVia Leo Valiani 67-77, 52025 Levane-Bucine (AR) Italy Tel.: +39 055 9119101 Fax: +39 055 9119191Email: [email protected] - Website: www.tetsistemi.com

T&T Sistemas Brasil LtdaRua Lafaiete, 394 – 1° Andar – Sala 5, Centro, CEP 14015-080 Ribeirão Preto – São Paulo - Brasil Tel. +16 3625-5448 - Fax +16 4009-8051

CC Anti-sourge Flexible control systemAntisurge Control System is a product that allows to protect your compressor from the sur-ge phenomenon. This protection allows you to extend the life and to improve the economic performance of your compressor. Internal algorithms compute the flow parameter and compare it with a design safety cor-rection and safety protection parameters. Depending on this comparison the control acts on the PID controller. The controller dynamically changes all the process parameters and control lines as a function of all variables involved in antisurge control.

• Proximity to surge calculations automatically adapt to any changing conditions in flow, pressure or temperature.

• High control flexibility, depending on instruments employed and their “in field” displace-ment.

• Suction header flow rate can be calculated as pressure and temperature discharge flow.

• Differentiate control behaviour depending on operating point position and approach rate to surge ld control lines.

• Maximum process performance and protection provided by an optimised combination of open and coop ontrol responses.

• Bumpless transfers between automatic and manual control modes.

• Complete integration control when optional or additional control elements, such as per-formance or lring.

• Controller output manipulation to satisfy the most restrictive condition encountered at any time.

General P&IDThe Antisurge can be divided in three different applications:• Flow element in suction• Flow element in discharge• Flow element interstage

From the implementation point of view the Antisurge controller can be:• Standalone PLC• SeeD implementation• Integrated PLC solution• Indipendently from the implementation type, the following I/Os need to be identified.