CATALOGUE2014 Revision 1.0
UNINTERRUPTIBLEPOWER SUPPLY (UPS)
Protecting Your Data
Your Inspirations. Our Innovations.
-
Table of Contents
Table ofContents
About Us - Company Prole
Online UPSProfessional Series (1P/1P) - TowerProfessional Series (1P/1P) - DualMaster Series (1P/1P) - TowerMaster Series (1P/1P) - ComboMaster Series (1P/1P) - 2-in-1 Rack/ TowerMaster Series (3P/1P) - TowerMaster Series (3P/1P) - Rack MountMaster Series (3P/3P) - TowerPower SeriesPPM Series
Line Interactive UPSPRO SFC SeriesPRO SeriesPRO-L SeriesPRO Rack/ Tower Series
Inverter UPSLCD Inverter Series
Auto Voltage RegulatorPVR Series
DC UPSPDC SeriesPBU Series
Solar UPSZonne SeriesPPS SeriesPCC SeriesPSI Hybrid SeriesPSI On-Grid Amnets SeriesPSI Off-Grid Offnetz SeriesPSI Off-Grid Haus SeriesPSS Series
Software & Accessories
Appendix
02
0404060812141821232530
3333353739
4141
4343
444445
464648495051525354
55
59
01
-
About Us - Company Prole
Our MissionAccentuate The Best For The E-generationPROLiNK aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy isbecoming more and more commonplace.
PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind, our products are crafted to enhance performance whether you are at work or play our products work harder, while you work smarter to achieve your desired results with less effort and better efciency.
Providing value to our consumers whether home or business users, remains a rm commitment of PROLiNK. With its wide range of quality products, PROLiNK makes it easy for home users to nd user-friendly yet affordable solutions for their technological needs, while business users are assured of reliable and secure solutions for their network infrastructure.
Our VisionIdeas, Innovation and InformationPROLiNK aims to be the key driving force behind technological changes and improvements in both developing and developed countries. With its strong focus on technology, our team sets high standards for itself in the areas of innovation, change and improvement so as to provide the next generation of users with products that are suita-ble for their technology advanced environments.
The small i in PROLiNK represents ideas, innovation and information three key pillars of growth that drive us towards achieving excellence in our eld of expertise and challenges us to think beyond our usual boundaries.
Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly productsmanufactured under the brand name PROLiNK since 1991. With more than two decades of professionalexperience in the information communications sector, PROLiNK is now renowned as a specialist in its eld,especially in the area of Back-up UPS products.
Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With its current network of sales ofces in more than 20 countries, customers can be assured that PROLiNK is able to provide the right solutions to meet the needs of both home and business users within each geographical location both efciently and effectively.
The companys quest for continuous improvement and quality assurance to its customers has earned us the ISO9001 quality certication since 1999. With its consistently strong commitment to quality, customers can be assured of they are getting true value - superior quality products at affordable prices.
02
-
Core ValuesSecured Information ManagementWith more than two decades of professional experience in providing backup power solutions to our customers, we are able to support our customers with superior technological know-how and expertise, as well as advice on market trends. At the same time, we are also fully committed to protecting the privacy of our customers and to manage condential information discreetly.
Innovative DesignOur products are carefully thought out to ensure that each item is designed to meet the needs of our customers. With the teams solid experience in the UPS market, customers can be certain that our designs are innovative yet functional, and suitable for each dynamic market that we have a presence in.
Superior Service StandardsStrict and rigorous testing makes up a huge part of our quality control procedures. We ensure that every item meets our strict standards from the individual components to the actual nished product.
Total Quality Assurance SystemOur products go through careful planning and checks at every stage of the production cycle - from the beginning stages of product design to the manufacturing and nally the actual delivery of the goods. This guarantees that our customers receive only the best quality goods of high reliability and durability. Our total quality system has been audited and approved by globally recognized bodies.
Range of UPSThe wide range of our products gives you an innite range of solutions:1. Online UPS2. Line Interactive UPS3. Inverter UPS4. DC UPS4. Solar UPS
03
About Us - Company Prole
-
Online UPS
Professional Series (1P/1P) - Tower
Online Professional Series 1kVA 6kVA
Professional Series (1P/1P) is an advanced yet affordable single-phase UPS system that uses on-line double conversiontechnology. It is designed to protect against power outages,disturbances and spikes, making them most suitable for voltage fluctuating environments. This device is able to providehigh-efciency charging with its high input power factor correction.
Professional Series is available in capacities ranging from 1000VA to 6000VA. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. Users can also have the option to top-up an additional isolationtransformer to obtain pure and clean power for their sensitivedevices.
True Double-Conversion Online UPS Wide input voltage range (110~300VAC) Input Power Factor correction of 0.98 Output Power Factor of 0.80 Generator compatible LCD User Interface Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface Smart battery charger designed to optimize battery performance Isolation transformer (optional)
Work-Stations ServersLocal AreaNetwork (LAN)
Small ComputerNetwork
Rear PanelFor 1kVA to 6kVA model1. Output receptacles2. AC input3. Input circuit breaker4. Network/Fax Modem Surge Protection5. Intelligent slot for communication port/ SNMP. (standard come with USB port)6. External battery connection (only available for L model)7. Output terminal8. Output circuit breaker9. Fan
5 6
9
432
1
5
9
3
27
1
8
46
PRO901S/LPRO902S/L
PRO903S/L
5
91
8
46
2 7
PRO906S/L
04
-
Online UPS
Full Specications
RS-232 Port (communication interface). AS-400 Card (External alarm indicator). SNMP Card for data communication via network connection. Output Isolation Transformer. External PDU & Maintenance Bypass Switch. (suitable for UPS up to 3kVA only)
Options
50 or 60Hz
110VAC < Vin < 290VAC @ 50% LOAD/ 168VAC < Vin < 300VAC @ 100% LOAD208/ 220/ 230/ 240VACNominal Voltage
Voltage RangeNominal FrequencyFrequency RangePower Factor
40 ~ 70Hz 0.98
6000 VA/ 4800 WCapacity 1000 VA/ 800 W 2000 VA/ 1600 W 3000 VA/ 2400 W
Valve regulated Lead Acid battery (Maintenance free batteries)TypeCapacity
Liner LoadNon-Liner Load
Recharge Time (Typical)Charging Current
Standard Model
Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI62040-2; EN62040-3Regulations
INPUT
MODELS PRO906S/ LPRO901S/ L PRO902S/ L PRO903S/ L
OUTPUT
BATTERY
MANAGEMENT
ENVIRONMENT
PHYSICAL
OVERLOAD
INDICATORS
EFFICIENCY
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MACUSB
1.5 seconds>130%
100% < Load < 110%
LCD Display
AC Mode
1% 3%
0.8
Static Regulation
Frequency RangeFrequency
Power FactorCurrent Crest Ratio
Voltage Distortion 3% THD
6% THD 7% THD
4% THD
Waveform
1.0 A (max)
47 ~ 53 Hz or 57 ~ 63 Hz
50Hz or 60Hz auto selection
Pure Sinewave
9AH
9 hours recover to 90% capacity
Up to 88%
3:1
10AH
TypeLong-Run Model Capacity
Charging Current 8.0 A (max) 6.0 A (max)
Overload warning only (No shutdown)110% < Load
-
06
Professional Series (1P/1P) - Dual
Online Professional Series1kVA 3kVA
Online True double-conversion Accepts Ultra Low Voltage inputs for special power environment Wide input voltage range (88-144VAC and 176-288VAC) at full load Input Power factor correction of 0.99 Output Power Factor of 0.80 LCD User Interface Complete galvanic isolation design offers full isolation and complete common mode noise rejection Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface
Professional Series (1P/1P) - Dual is an advanced yet affordable single-phase UPS system that uses on-line double conversiontechnology with 2 different input voltage ranges. It is designed to protect against power outages, disturbances and spikes, making them most suitable for voltage fluctuating environments.
Professional Series (1P/1P) Dual is most suitable to be used in areas that are plagued by voltages that are as low as 100V. With the advanced double-conversion technology, the dual series is able to regulate and maintain consistent output even when it is fully loaded. Also, this device is able to provide full isolation and complete common mode noise rejection from complementary equipment. The Dual Series is available in various capacities, ranging from 1000VA to 3000VA.
Online UPS
Rear Panel
PRO902D S/L PRO903D S/L
Work-Stations ServersLocal AreaNetwork (LAN)
Small ComputerNetwork
For 1kVA to 3kVA model1. Output receptacles2. AC input3. Input circuit breaker4. Network/Fax/Modem surge protection5. Intelligent slot for communication port/SNMP (standard come with USB port)6. External battery terminal (only available for Long-run model)7. Output terminal8. Output circuit breaker9. Fan PRO901D S/L
5
9
9
6
1
2
34
5
9
9 6
1
2
9
4
5
9
9
9
86
1
2 7
4
-
07
Online UPS
Full Specications
50 or 60Hz
88VAC ~ 144VAC and 176VAC ~ 288VAC (auto sensing) 208/ 220/ 230/ 240VACNominal Voltage
Voltage RangeNominal FrequencyFrequency RangePower Factor
45 ~ 65Hz 0.99
Capacity 1000 VA/ 800 W 3000 VA/ 2400 W
Valve regulated Lead Acid battery (Maintenance free batteries)TypeCapacityRecharge Time (Typical)Charging Current
Standard Model
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3Regulations
INPUT
MODELS PRO901D S/L2000 VA/ 1600 W
PRO902D S/L PRO903D S/L
OUTPUT
BATTERY
MANAGEMENT
ENVIRONMENT
PHYSICAL
OVERLOAD
INDICATORS
EFFICIENCY
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MACUSB/ RS-232
1.5 seconds>130%
100% < Load < 110%
LCD Display
AC Mode
1%
0.8
Static Regulation
Frequency RangeFrequency
Power FactorCurrent Crest Ratio
Voltage Distortion Linear LoadNon-Linear Load 6% THD
2% THD
Waveform
1.0 A (max)
47 ~ 53 Hz or 57 ~ 63 Hz
50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH
4 hours recover to 90% capacity
Up to 88%
3:1
TypeLong-Run Model Capacity
Charging Current
Overload warning only (No shutdown)110% < Load < 130% 30 seconds
Depending on the application4.0 A or 8.0 A (max.)
Depending on the application
208/ 220/ 230/ 240VACOutput Voltage
423 x 145 x 332
426 x 190 x 448
421 x 190 x 448
-
08
Online UPS
Master Series (1P/1P) - Tower
Online Master Series1kVA 10kVA
Master Series (1P/1P) is a single-phase UPS system that employs a true online double-conversion technology. It is designed to deliver clean and high quality electrical power for devices such as small computer centres, servers, telecom applications, lab testing equipments and industrialapplications. The Master series (1P/1P) comes with a wide input voltage range that protects devices against outages, disturbances and spikes. In addition, this device comes with a smart battery charger that optimizes the battery performance, ensuring longer lasting battery life. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The Master series (1P/1P) also comes in various capacities ranging from 1kVA to 10kVA to suit your needs. The 6kVA and 10kVA UPS system comes with 2 additional features; an internal bypass system and a parallel redundant system. An internal bypass system allowing continuous power is integrated for convenience when maintenance is necessary and a parallel redundant system that allows two UPS models to operate in parallel as backup for each other.
True Double-Conversion Online UPS Wide input voltage range (110~300VAC) Input Power Factor correction of 0.99 Output Power Factor 0.80 Generator compatible LCD User Interface Choice between RS-232 communication port or USB / RS-232 / AS400 / SNMP interface Smart battery charger designed to optimize battery performance
Work-Stations ServersLocal AreaNetwork (LAN)
Small ComputerNetwork
Rear PanelFor 1kVA to 3kVA model1. Programmable outlets: connect to non-critical loads2. Output receptacles: connect to mission critical loads3. AC input4. Input circuit breaker5. Network/ Fax/ Modem surge protection6. Emergency power off function connector (EPO)7. USB communication port8. RS-232 communication port9. SNMP intelligent slot10. External battery connection (only available for L model)11. Output terminal12. Output circuit breaker13. Fan
PRO802S/L PRO803S/LPRO801S/LPRO8015S/L
9
56
87
13
10
4
32
1
9
5
2 1
7 8
6
43
1013
13
9
5
2 1
7 8
6
3
4
1012
11
13
13
-
09
Online UPS
For 6kVA to 10kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel model)5. Parallel port (only available for parallel model)6. Intelligent slot7. Charger fan8. Power stage fan9. Maintenance bypass switch10. Input circuit breaker11. Input/Output terminal12. Output terminal 113. Output terminal 214. External battery terminal (only available for Long-run model)15. Utility input terminal16. Output IEC Socket
9
5 521
78
8
643
1512 13
14
16 11
10
PRO806S/LPRO810S/L
Battery PackFor 1kVA to 3kVA model
For 6kVA to 10kVA model
Model
Battery Type
Battery Number (max)
Dimension (DxWxH) mm
Weight (kg)
G6
6 pcs
18
6 pcs
397 145 220
20
12 pcs
36
G18G12
12 pcs 18 pcs 18 pcs
421 190 318
40 55
12V9AH12V7AH 12V7AH 12V9AH 12V7AH 12V9AH
535 190 318
61
Model
Battery Type
Battery Number (max)
Dimension (DxWxH) mm
Weight (kg)
40 pcs
109
G40 G60
40 pcs 60 pcs 60 pcs
592 250 576
125 166
12V7AH 12V9AH 12V7AH / 12V90AH
830 250 576
190
-
10
Online UPS
Full Specications
Options AS-400 Card (External alarm indicator) SNMP Card for data communication via network connection. Output Isolation Transformer. External PDU & Maintenance Bypass Switch. (Only suitable for UPS that are up to 3kVA)
A derate will occur during the Frequency converter mode (Capacity is reduced to 60%) and when the output voltage is adjusted to 208VAC (Capacity is reduced to 80%). If the UPS is installed in a location where the altitude is above 1000m, the output power must be lowered by one percent for every 100m covered. L stands for Long-run modelS stands for Standard modelI stands for Isolation Transformer (Optional)*All specications, designs and contents are subject to change without prior notice.
50 or 60Hz
110VAC
-
11
Online UPS
Programmable Outlets (P1)- connect to non-critical devices
True double-conversion Online UPSA true double conversion UPS will provide clean, high level quality power to fully protect mission-criticaldevices such as sensitive networks, small computer centers, servers, telecom applications, as well as for industrial applications.
Higher Accuracy for Output VoltageThe advanced control rmware allows the Master Series (1P/1P) to achieve higher accuracy with the output voltage tolerance of +/- 1%. The device is applicable for the use with critical test and IT equipments.
Smart Battery Charger Design to OptimiseBattery PerformanceMaster Series (1P/1P) 1-3kVA models are equipped with a 2-stage charger design to guarantee precise battery discharge time. The charging voltage is alsoautomatically adjusted according to the ambient temperature, to lengthen the service life of the battery.
The 6kVA and 10kVA models come with an additional extendable charger that allows for large-capacity battery charging.
DSP Technology (Applies for the above models)A DSP controller improves the performance andefciency of the UPS.
Maintenance Bypass Available For 6kVA And Above ModelsInternal bypass assures continuous power to critical devices during UPS maintenance.
Optional Hot Standby and N+X ParallelRedundant System (Available for Models ranging from 6kVA and above)An internal bypass system allowing continuous power is integrated for convenience when maintenance isnecessary and a parallel redundant system that allows two UPS models to operate in parallel as backup for each other.
Output Power factor of 0.8As compared to the online UPS models in the current market, the Master Series (1P/1P) provides better output power factor of up to 0.8. This unit is able to offer higher performance and efciency for your critical applications.
Wide Input Voltage Range (110 V -300 V)Master Series (1P/1P) can still provide stable power to connected devices under unstable power environments.
50/60 Hz Frequency Converter ModeLock output frequency at 50Hz or 60Hz to suit power sensitive equipments.
ECO Mode Operation For Energy SavingOffers efciency as high as 97% to cut energy usage & cost. UPS power application via static bypass, timely returning to online double conversion when the need arises.
Emergency Power Off (EPO) FunctionThis feature can protect the personnel and theequipment in the case of re outbreak or other types of emergency.
SNMP + USB + RS-232 MultipleCommunication port for Models ranging from 1 to 3kVA.This feature allows either the USB or RS-232communication port to simultaneously operate with the SNMP interface.
Programmable Power Management Outlets The programmable power management outlets allow users to easily and independently control the load segment. In the event of a power failure, this feature enables users to manage and extend the battery time for mission critical devices by shutting down the non-critical devices.
-
12
Online UPS
Master Series (1P/1P) - Combo
Online Master Series6kVA 10kVA
True double-conversion on line UPS DSP technology guarantees high performance Wide input voltage range (110-300 VAC) Active input power factor correction of 0.99 Output power factor of 0.8 50Hz/60Hz frequency converter mode Standard backup UPS and long backup UPS in one integrated unit Charging current can be adjusted via LCD or software (1A~6A) Emergency power off function (EPO) Comes with a USB and PS-232 communication port Comes with a mini slot for AS-400 / SNMP communication card Comes with a maintenance bypass function
Work-Stations ServersLocal AreaNetwork (LAN)
Small ComputerNetwork
Rear PanelFor 6kVA to 10kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Intelligent slot5. Power stage fan6. Maintenance bypass switch7. Input circuit breaker8. Input/Output terminal9. External battery terminal (only available for Long-run model)10. Battery Compartment (only available for Standard model)
Master Series (1P/1P) - Combo is a single-phase UPS system that employs a true online double-conversion technology. It is designed to deliver clean and highquality electrical power for devices such as small computer centres, servers, telecom applications and industrial applications. Designed with a small footprint, this device ensures that it will t into any corner of your small ofce.
Master Series (1P/1P) - Combo series comes with a wide input voltage range that protects devices against the outages, disturbances and spikes. Fitted with a smart battery charger design, this device is able to optimize its battery performance, ensuring longer lasting battery life. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The Combo series are available in the following capacities; 6kVA and 10kVA.
PRO806C/PRO810C
PRO806CL/PRO810CL
9
5
6
8
7
4
321
5
6
8
7
4
321
10
-
13
Online UPS
Options AS-400 Card (External alarm indicator) SNMP Card for data communication via network connection. Output Isolation Transformer.
50 or 60Hz
110VAC
-
14
Online UPS
Master Series (1P/1P) - 2-in-1 Rack/ Tower
Online Master Series 1kVA 10kVA
Master Series (1P/1P) 2-in-1 Rack/Tower is a single-phase UPS system that employs a true onlinedouble-conversion technology. This device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a floor-standing tower or in a mounted position using a 19-inch rack mount bracket. With its high density output power factor of 0.9, this device is able to provide outstanding performance and efciency to meet the requirements of a mission critical environment.
This 2-in-1 Rank/Tower UPS is brilliantly designed with a hot-swapping battery feature to facilitate thereplacement of the existing batteries without the hassle of having to shut the devices down. On top of that, models with a 6kVA and 10kVA capacity comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. High voltage battery chargers and battery extension assembly are made available for longer runtime applications. The PROLiNK 2-in-1 Rank/Tower UPS comes with a wide range of capacities from as low as 1kVA to as high as 10kVA to accommodate to your every need.
True Double-Conversion Online UPS Rack or Tower design Wide input voltage range (110~300VAC) Input Power Factor correction of 0.99 Output Power factor of 0.90 50/60Hz frequency converter mode Hot-Swappable battery design Emergency Power Off (EPO) function ECO Operation Mode provides energy conservation Generator Compatible Option available for long-run models to expand the charger capacity to 8A Multiple communication interface (SNMP/USB/RS-232) Smart battery charger is designed to optimize overall battery performance Selectable output voltage via LCD panel
Work-Stations Servers 19 RackMount
Local AreaNetwork (LAN)
Small ComputerNetwork
-
15
Online UPS
Rear PanelFor 1kVA to 3kVA model1. Programmable outlets: Connect to non-critical loads2. Output receptacles: Connect to mission-critical loads3. AC input4. Input circuit breaker5. Network/Fax/Modem surge protection6. Emergency power off function connector (EPO)7. USB communication port8. RS-232 communication port9. SNMP intelligent slot10. External battery terminal (only available for Long-run model)11. Output IEC320-C20 connector12. Fan
For 6kVA to 10kVA model1. Programmable outlets: Connect to non-critical loads2. Output receptacles: Connect to mission-critical loads3. AC input4. Input circuit breaker5. Network/Fax/Modem surge protection6. Emergency power off function connector (EPO)7. USB communication port8. RS-232 communication port9. SNMP intelligent slot10. Battery connection11. Input terminal12. Fan13. Parallel port (only available for parallel model)14. External maintenance by-pass switch connection15. Output Terminal16. Ground
PRO806RS/RLPRO810RS/RL
69 47
7
121014
13
11 16 15
Battery PackFor 1kVA to 10kVA model
Model
Battery Type
Battery Number (max)
Dimension (DxWxH) mm
Weight (kg)
G8R
8 pcs
480 438 88
31.1
G12R G20R
12 pcs 20 pcs
43.3 57
12V9AH 12V7AH 12V9AH
580 438 133600 438 88
63
PRO803RS/RL
5 12 12 10 6
7
89
1
2
311
4
PRO801RS/RL PRO8015RS/RL PRO802RS/RL
5 12 106
7
89
1
2
3
4
-
16
Online UPS
AS-400 Card (External alarm indicator) SNMP Card for data communication via network connection MODBUS Card (communication interface) Universal Rackmount Slider for installation in rack cabinets External PDU & Maintenance Bypass Switch (Only suitable for UPS that are up to 3kVA) Maintenance Bypass Switch [MBS] (Only available in UPS ranging from 6 to 10kVA) External Automatic Transfer Switch (ATS)
Options
Full Specications
50 or 60Hz
110VAC
-
17
Online UPS
Programmable Outlets (P1)- connect to non-critical devices
True Double-conversion Online UPSA true double conversion UPS system will provide clean and high quality electrical power to fully protect mission critical systems such as sensitive networks, small computer centers, servers, telecom applications and industrial applications.
Programmable Power Management OutletsThe programmable power management outlets allow users to easily and independently control the load segment. In the event of a power failure, this feature enables users to manage and extend the battery time for mission critical devices by shutting down the non-critical devices.
ECO and Advanced ECO Mode for Energy SavingIt allows the UPS to operate in high efciency of up to 97% during energy saving ECO mode and 98% inoperation mode. In the event of an electrical AC failure, the inverter will automatically step-in and provideelectrical supply to the connected systems.
Emergency Power Off Function (EPO)This feature provides adequate protection for the user and the equipment against hazards such as re break-out or other emergencies.
Hot-swapping Battery DesignThe hot-swapping battery feature helps to facilitate the replacement of the existing batteries without the hassle of having to shut the devices down.
Long Battery Runtime Models AvailableOur Long Battery Runtime Models offers the flexibility to add-on additional external batteries to provide a longer back-up time.
User-friendly LCD DisplayThe front panel digital display comes with an auto-rotation feature that caters to your installationpreference; either vertically or wall mounted.
Rack / Tower DesignThis device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a floor-standing tower or in a mounting position using a 19-inch rack mount bracket.
High Output Crest RatioThe Master (1P/1P) 2-in-1 Rack/Tower Series is designed with a high output crest ratio of 5:1 that allows the device to be extremely compatible with equipment such as compressors, generators and motors.
Output Voltage Regulation (tolerance +/- 1%)The Master (1P/1P) 2-in-1 rack / Tower Series is able to produce extremely stable and clean electrical power with its high efciency output voltage regulator. This regulator is able to achieve a tolerance of +/- 1%, making it extremely compatible even with sensitive power supplies.
Output power factor 0.9Master (1P/1P) 2-in-1 rack/Tower Series is ahigh-density UPS system with an output power factor of 0.9. With this high power factor, the Master series is able to provide higher performance to critical applications.
Rack Display Tower Display
19 Rack-mounting Floor-standing Tower
-
18
Online UPS
Master Series (3P/1P) - Tower
Online Master Series 10kVA 30kVA
True Double-Conversion Online UPS DSP technology guarantees high performance Input Power Factor Correction 0.99 Active power factor correction in all phases 50/60Hz frequency converter mode Multiple communication interface (SNMP/USB/RS-232)
Wide input voltage range Output Power Factor 0.80 Comes with a maintenance bypass function Optional N+X parallel redundancy Emergency Power Off (EPO) function Isolation transformer (Optional)
DataCentre
Electro-MedicalDevice
StoragePLCS
EmergencyAlarm
Devices
E-Business(Server Farms,ISP/ASP/POP)
Local AreaNetwork
(LAN)
TelecommunicationDevices
PRO83110S/L
Rear PanelFor 10kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel model)5. Parallel port (only available for parallel model)6. Intelligent slot7. Charger fan8. Power stage fan9. Maintenance by-pass switch10. Input circuit breaker11. Output circuit breaker for receptacles12. Output receptacles: connect to mission-critical loads13. Input/Output terminal14. External battery connector (Only available for Long-run Model)
5 5
13
14
12
10
7
8
8
9
61 2 3 4
11
Master Series (3P/1P) three-phase input / single-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as mid-sized business servers,telecommunication systems and industrial equipment. The (3P/1P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment.
This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to 30kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Master series (3P/1P) UPS also offers the option of adding on an isolation transformer to suit your requirements.
-
19
Online UPS
PRO83115LPRO83120L
PRO83115SPRO83120S
PRO83130S/LPRO83130L
For 15kVA to 30kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel model)5. Parallel port (only available for parallel model)6. Intelligent slot7. Charger fan8. Power stage fan9. Maintenance by-pass switch10. Input circuit breaker11. Output circuit breaker for receptacles12. Output receptacles: connect to mission-critical loads13. Input/Output terminal14. Output Terminal: Connect to mission-critical loads15. Programmable Output terminal: Connect to non-critical loads16. External battery terminal (only available for Long-run model)17. Utility input terminal18. Grounding terminal (only available for parallel system)
5 5
11
18
10
7
78
8
9
61 2 3 4
5 5
11
10
7
78
8
9
61 2 3 4
For 15K & 30K modelFor 10K model
14 15 1715 16 1714
18
AS-400 Card (External alarm indicator) SNMP Card for data communication via network connection MODBUS Card (Communication interface) Output Isolation Transformer
Options
-
20
Online UPS
50 or 60Hz300VAC < Vin < 480VAC360/ 380/ 400/ 415VACNominal Voltage
Voltage RangeNominal FrequencyFrequency RangePower Factor
46 ~ 64Hz 0.99
Capacity 10 kVA/ 8 KW 15 kVA/ 12 KW 20 kVA/ 16 KW
Valve regulated Lead Acid battery (Maintenance free batteries)TypeCapacity
Liner LoadNon-Liner Load
Recharge Time (Typical)Charging Current
Standard Model
Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3Regulations
INPUT
MODELS PRO83110S/ L PRO83115S/ L PRO83120S/ L30kVA / 24kW
PRO83130 (S/L)
OUTPUT
BATTERY
MANAGEMENT
ENVIRONMENT
PHYSICAL
OVERLOAD
INDICATORS
EFFICIENCY
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MACUSB
1 second>130%
100% < Load < 110%
LCD Display
AC Mode
1%
0.8
Static Regulation
Frequency RangeFrequency
Power FactorCurrent Crest Ratio
Voltage Distortion 2% THD
6% THD 5% THD 5% THD 7% THDWaveform
1.0 A (max) 2.0 A (max) 4.0 A (max)
4.0 A (max) 12.0 A (max)
50 ~ 60Hz 0.1 Hz50Hz or 60Hz auto selection or selectable
Pure Sinewave
9AH9 hours recover to 90% capacity
Up to 89%
3:1
TypeLong-Run Model Capacity
Charging Current
10 minutes110% < Load < 130% 1 minute
Depending on the applicationDepending on the application
200/ 208/ 220/ 230/ 240VACOutput Voltage
592 250 576164
37
815 250 826
592 250 826234
64
815 300 1000
815 250 826
IP20
-
21
Master Series (3P/1P) - Rack Mount
Online Master Series 10kVA 20kVA
True double-conversion DSP technology guarantees high performance Output Power Factor 0.8 Wide input voltage range Active power factor correction in all phases 50Hz/60Hz frequency converter mode
Eco mode operation for energy saving (ECO) Emergency power off function (EPO) Generator compatible Multiple communication interface (SNMP/USB/RS-232) Adjustable battery numbers Optional N+X parallel redundancy
Master Series (3P/1P) Rack three-phase input / single-phase output, true online double conversion UPS systemguarantees consistent and quality electrical power to protect your mission critical applications such as mid-sizedbusiness servers, telecommunication systems and industrial equipments. This (3P/1P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe yourequipment.
This Voltage Frequency Independent (VFI) system is available in capacities from 10kVA to 20kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage switching characteristics during generator operation. Aninternal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Master series (3P/1P) Rack UPS also offers the option of adding on an isolation transformer to suit your requirements.
Online UPS
DataCentre
19 RackMount
StoragePLCS
EmergencyAlarm
Devices
Local AreaNetwork
(LAN)
TelecommunicationDevices
5
12 10
7 8
9
6 6
1
2
3
4 4 4
11
5
12
10
7
8
9
6 6
6 6
1
23
4
4
411
Rear PanelFor 10kVA to 20kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Parallel port (only available for parallel model)5. Intelligent slot6. Fan7. External maintenance by-pass switch connection8. Input circuit breaker9. Input/Output terminal10. Output terminal11. Battery terminal12. Input terminal
PRO83110RS/RL
PRO83120RS/RL
-
22
Online UPS
AS-400 Card (External Alarm Indicator) SNMP Card for data communication via network connection MODBUS Card (Communication interface) Universal Rackmount Slider for installation in rack cabinets External Maintenance Bypass Switch (Only available with 10kVA model)
Options
Full Specications
50 or 60Hz300VAC
-
23
Online UPS
Master Series (3P/3P) - Tower
Online Master Series 10kVA 30kVA
True Double-Conversion Online UPS DSP technology guarantees high performance Input Power Factor Correction 0.99 Active power factor correction in all phases 50/60Hz frequency converter mode Multiple communication interface (SNMP/USB/RS-232)
Wide input voltage range Output Power Factor of 0.80 Comes with a maintenance bypass feature Optional N+X parallel redundancy Emergency Power Off (EPO) function Isolation transformer (Optional)
DataCentre
Electro-MedicalDevice
StoragePLCS
EmergencyAlarm
Devices
E-Business(Server Farms,ISP/ASP/POP)
Local AreaNetwork
(LAN)
TelecommunicationDevices
Master Series (3P/3P) Tower three-phase input / three-phase output, true online double conversion UPS system guarantees consistent and quality electrical power to protect your mission critical applications such as small server room, medical devices, telecommunication facilities and industrial processes. This (3P/3P) UPS is designed with a wide input voltage range to handle voltage fluctuating situations and a high accuracy output voltage to fail-safe your equipment.
The Master Series (3P/3P) UPS system is available in capacities from 10kVA to 30kVA. By adopting the latest IGBT technology, this device is able offer excellent voltage-switching characteristics during generator operation. An internal bypass system allowing continuous power is also integrated for convenience when maintenance is necessary. In addition, this device comes with a parallel redundant system that allows two UPS models to operate in parallel and as backup for each other. The Tower series UPS also offers the option of adding on an isolation transformer to suit your requirements.
Rear PanelFor 10kVA to 30kVA model1. RS-232 communication port2. USB communication port3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel model)5. Parallel port (only available for parallel model)6. Intelligent slot7. Charger fan8. Power stage fan9. Maintenance bypass switch10. Bypass Input Circuit Breaker (Only available for dual input unit)11. Input circuit breaker12. Input/Output terminal13. External battery terminal (only available for Long-run model)
12
10 13
7
7
68
8
9
1 2 3 4
11
5
PRO83310S/LPRO83320S/LPRO83330S/L
-
24
Online UPS
AS-400 Card (External Alarm Indicator) SNMP Card for data communication via network connection MODBUS Card (Communication interface) Output Isolation Transformer
Options
Full Specications
50 or 60Hz300VAC
-
25
Online UPS
Power Series
Online Power Series 15kVA 120kVA
Online double conversion technology with DSP control Harmful effects of harmonic injection are eliminated with the employment of Adaptive Feed Forward Cancellation (AFC) technology Very low input current distortion (THDi < 1%) Input power factor 0.99 at 10% load Output efciency up to 95% Control designed to withstand all kinds of loads Variety of communication options available Optional N+X parallel redundancy Remaining backup time calculation Optional isolation transformer
DataCentre
Electro-MedicalDevice
StoragePLCS
EmergencyAlarm
Devices
E-Business(Server Farms,ISP/ASP/POP)
Local AreaNetwork
(LAN)
TelecommunicationDevices
Power Series (3P/3P) three-phase input / three-phase output, true online double conversion UPS system guarantees to supply consistent and quality electrical power to protect your mission critical applications such as data centres, medical equipments and call centres. Harmful effects of harmonic injection are eliminated with the employment of Adaptive Feed Forward Cancellation (AFC) technology. With a UPS system that reflects low harmonicdistortion and high input power factor, it is able to lower installation costs by utilizing smaller cables and miniature circuit breakers (MCB).
Our team of specialists has gathered together to revolutionize the UPS usability by adding in a 5.7 LCD monitor display with all information and alarm notications viewable within a single display. To ensure our products are user centered, our group of specialist has also adopted a front access concept to create a UPS system that is easy for users to carry out preventative maintenance and replacement activities. In addition, this device comes with a parallelredundant system that allows four UPS models to operate in parallel. An option of anadditional isolation transformer is also available to suit your requirements. The Power series is available in models ranging from 15kVA to 120kVA.
Rear Panel (Internal)For 15kVA to 80kVA model1. Relay interface2. Emergency Power Off (EPO)3. RS-232 COM ports4. Intelligent Slow5. Input circuit breaker6. Maintenance bypass switch7. Output switch8. Battery switch9. System Terminal10. Parallel port (only available for parallel model)
5
10
76
9
12
3
8
4
PRO73315S/SIPRO73320S/SI
PRO73330S/SIPRO73340S/SI
5
10
76
9
12
3
8
4
PRO73360S/SIPRO73380S/SI
5
10
76
9
12
3
8
4
-
PRO733100SPRO733120S
Full Specications
50 or 60Hz300VAC
-
Online UPS
SNMP Card for data communication via network connection MODBUS Card (Communication interface) Output Isolation Transformer
Options
50 or 60Hz300VAC
-
Online UPS
The Most Versatile Solution For PowerProtectionThe Power Series is designed with the new state of art transformerless PWM technology that can be easily adapted to any kinds of complicated loads such as the non-linear systems (IT systems), highly inductive/capacitive loads, high-density discharge lamps and induction motors. The Power series is designed with 2 important criterions in mind; maximum efciency and energy conservation. The unit also comes with a small form factor to allow for minimum installation effort. Furthermore, a parallel redundant system is integrated to allow two UPS models to operate in parallel as backup for each other. The Power Series is available incapacities ranging from 15 to 120kVA.
Online Double Conversion Technology with DSP ControlThe Power Series is able provide a higher load up-time and effective insulation against network disturbance with its online double conversion technology. A Digital Signal Processor (DSP) controller improves theperformance and efciency of the UPS.
Advanced Control with Adaptive Feed Forward Cancellation (AFC) TechnologyBy cancelling both the input current and the output voltage harmonics, the harmful effects of harmonic injection can be eliminated and this enhances the load integrity.
Low Input Current Distortion (THDi < 1%)AFC cells are used to achieve extremely low distortion values. The Power series is able to obtain a low input current distortion at THDi < 1% under full load and a THDi < 5% under smaller load (i.e. 10% of load). This will prevent distortion of electrical network upstream and thus, result in the reduction of cable usage and protective devices in the electrical network.
Input Power Factor 0.99 At 10% LoadLower power losses would result in reducedconsumption, lower operation and maintenance costs.
Output Efciency of up to 95%Designed with a DSP controller and fourth generation IGBT transistors, the UPS is able to achieve extremely high efciency of up to 95%. With such high ratings, components in the UPS are not only protected but also prolonged due to the decrease in heat losses.
Small Form FactorUtilizes a transformerless technology allows the design of the UPS to be lighter and smaller.
1,20
1,00
0,80
0,60
0,40
0,20
0,000% 25% 50%
LOAD
INPUT POWER FACTOR
PFi
n
100%
75%
50%
25%
0%0%
SERIES TIPICAL EFFICIENCY
25% 50%
EFFI
CIE
NC
Y
LOAD
28
-
Online UPS
Front Access conceptAn important consideration has been given during the UPS design phase to create a system that allows users to access the units electronic cards and powercomponents with minimum effort. All electronic boards and components can be accessed from the front panel for easy maintenance and replacement activities.
Versatile Single-Phase / Three-Phase set-upsThis highly versatile UPS is designed with different types of setting-up options; Three-phase input / Three-phase output (III/III) Three-phase input / Single phase output (III/I)
Control Components are designed towith stand all kinds of loadsIn the Power Series, the control components are designed to withstand all types of loads. These include loads such as; resistive, capacitive, non-linear,high-density discharge lamps, induction motors, speed drives etc. This makes the UPS extremely compatible with many types of electronics. Better yet, the UPS comes with a wide array of parameters that can be programmed locally or remotely to t different types of environment.
N+1 RedundancyA parallel redundant system allows 4 UPS models to operate in parallel and as backup for each other.
Variety Of Communications And OptionAvailableThe UPS has provided the following standardcommunication selections: Relay interface RS-232/485 port 1 SNMP slot Modbus RTU / SEC protocol 2 connectors for parallel connection
Made of 60% RecyclableMaterialsWhen it comes to conserving the environment, PROLiNK is committed to play a part by designing their UPS products using recyclable materials.
Back-up Time indicatorWith the use of simple algorithms, an estimatedremaining back-up time can be calculated andindications will be reflected on a LCD panel.
5.7 Multiple Languages Graphical LCDDisplayOur team of specialists has gathered together torevolutionize the UPS usability by adding in a 5.7 LCD monitor display with all information and alarmnotications viewable within a single display.
29
-
30
Online UPS
PPM Series
PROLiNK PowerModular (PPM)UPS System
N+1 parallel redundancy Online double conversion technology Output Power Factor of 1 Modular design decreases MTTR High scalability Internal maintenance bypass available Adjustable charging current Highly interactive 5.7" LCD design
PROLiNK PPM Series modular three-phase input / three-phase output online double conversion UPS takes scalability to a whole new level. Based on a scalable design, the PPM comes with a wide range of capacity, ranging from as low as 30kVA to as high as 210kVA. The PPM series is designed with a N+X parallel redundancy system that allows two or more UPS modules to operate in parallel and as back-up for each other. This unit provides an ideal protection for data centers, telecommunication facilities and other critical applications. Up to seven 30kVA modules can be tted into a standard cabinet to simplify maintenance and replacement activities. The PPM Series guarantees a low mean-time-to-repair (MTTR), giving users a shorter elapsed time between the point of repair and the point of equipmentrecovery.
High Efciency Online Double ConversionTechnologyPROLiNK PPM is designed with the latest online double conversion technology that provides a high efciency rating of 96%. With such a high efciency rating, the PPM can save you hundreds of dollars each year.
High ScalabilityBased on a scalable design, the PPM Series simplies future expansion by making UPS units easily upgradable. This architecture allows you to meet power demands by adding additional modules vertically in a single rack enclosure.
Unity Output Power FactorWith a unity output factor (kVA = kW), the PROLiNK PPM UPS system is 100% compatible with today's high power factor loads. It is able to meet the latest serverrequirements, giving the best value for your ITinvestments.
Modular Design Lowers MTTRThe modular design ensures uninterrupted power supply during UPS maintaining and replacing activities. Also, the PPM Series guarantees a low mean-time-to-repair (MTTR), giving users a shorter elapsed time between the point of repair and the point of equipment recovery.
DataCentre
Electro-MedicalDevice
StoragePLCS
EmergencyAlarm
Devices
E-Business(Server Farms,ISP/ASP/POP)
Local AreaNetwork
(LAN)
TelecommunicationDevices
-
31
Online UPS
N+X Parallel RedundancyThe PPM series is designed with a N+X parallelredundancy system that allows two or more UPSmodules to operate in parallel and as back-up for each other.
Ease Of Installation and MaintenanceWith a built-in maintenance bypass feature, the UPS is able to deliver continuous power to the critical load during maintenance. Better yet, the PPS comes with a front access concept to facilitate installation.
Adjustable Charging CurrentPROLiNK PPM comes with a maximum charging current of up to 8A for each individual module. The charging current can be adjusted based on the necessaryrequirement.
High Overload CapabilityPROLiNK PPM supports 110% overload for 60 minutes,120% for 10 minutes and 150% for 1 minute.
5.7 LCD Graphic Mimic PanelA multilingual 5.7" graphic LCD screen is integrated as part of the design to provide users with visual information and advanced control abilities.
The PROLiNK PPM90 is a compact stand alone UPS system that provides the best backup solution for small and medium loads. This unit comes with a standard EIA height of 30U and is able to t capacities ranging from 30kVA to 90kVA in the same cabinet. With features such as N+1 redundancy and the capability for future expansion, the PROLiNK PPM90 is denitely able to make your backup experience an absolute cinch.
PPM90
No. Of Module
1
2
3
Capacity
60kVA
90kVA
Dimension
600 x 1100 x 1485 (30U) mm
30kVA
Exterior Interior
The PROLiNK PPM210 is a standalone UPS system that comes with a standard EIA height of 42U. This unit is able to t 7 x 30kVA modular redundancy in the same cabinet. Even better, the PPM210 has the capability to manage future capacity expansion of up to 210kVA, making the PPM210 the best backupsolution for greater loads.
PPM210
No. Of Module
1
2
3
4
5
6
7
Capacity
60kVA
90kVA
120kVA
150kVA
180kVA
210kVA
Dimension
600 x 1100 x 2030 (42U) mm
30kVA
Exterior Interior
-
32
Full Specications
50/60Hz (auto-selectable)40Hz ~70Hz
> 0.99< 3%
305 ~ 477 Vac @Full load, 208 ~ 477 Vac @ 150%
1% THD (Linear Load); 4% THD (Non-linear Load)
> 96%
Voltage Regulation (Transient)Voltage Regulation (Steady state)
Nominal FrequencyFrequency Range
Overload Capability
Harmonic Distortion
Efciency
5% Typical 1% Typical (balanced load); 2% Typical (unbalanced load)
Active Power (VA) 30kVA30kWatt
8A (Adjustable)
2.25V/Cell2.35V/Cell
Yes
0 ~ 40C0 ~ 95% non-condensing
-
33
Line Interactive UPS
PRO SFC Series
Super Fast Charging Line Interactive Series650VA - 1200VA
Built-in super fast charger, battery can be recharged to 90% of its capacity within 2-4 hours Excellent microprocessor control guarantees high reliability Boost and buck AVR for voltage stabilization Auto restart while AC is recovering Simulated sine wave Off-mode charging Cold start function Optional USB/RS-232 communication port and RJ-11/RJ-45 protection
PROLiNK SFC series is a single-phase input/ single-phase output Line-Interactive UPS system with PROLiNKs latest Super-Fast Charging technology. This cutting-edge technology is able to recharge the battery back to 90% of its capacity within 2-4 hours, and is ideal for providing stable backup power to home/ small ofce applications. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage. This prevents under voltage brownouts and over voltage surges. The unit also comes with universalsockets to provide better compatibility with a wider range of devices.
Rear PanelFor 650VA to 1200VA model1. AC Input2. Backup Output3. Bypass Output (without battery back up)4. USB Port (Only available in SFCU series)5. RJ11
PC Printer Work-Stations
PRO1200SFC/ SFCU
5
12
2 3
4
PRO700SFC/ SFCU PRO850SFCU
12
2
4
5
1
2
2
4
-
34
Line Interactive UPS
Full Specications
50 or 60Hz (Auto Sensing)25%
220/ 230/ 240VACNominal VoltageVoltage RangeNominal Frequency
Capacity650VA
Watt1200
1 x 12V8.2AH 1 x 12V10AH 2 x 12V8.2AHNumber of BatteryRecharge Time (Typical)
Battery Mode Sounding every 10 secondsLow Battery Sounding every second
Overload Sounding every 0.5 secondsBattery Replacement Alarm Sounding every 2 seconds
Fault Continuously Sounding
INPUT
MODELS PRO700SFC/ SFCU850
360 600480
PRO850SFCU PRO1200SSFC/ SFCU
OUTPUT
BATTERY
PROTECTION
MANAGEMENT
ENVIRONMENT
PHYSICAL
INDICATION
ALARM
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MACUSB/ RS-232
LED Display
Sounding
Simulated SinewaveTransfer Time (Typical)Frequency
Waveform2 - 8ms 2 - 6ms, 10ms (max)
50Hz or 60Hz 1Hz
Full Protection Short Circuit, Overload, Discharge and Overcharge Protection
2 4 hours recover to 90% capacity
AC Mode Green LightingBattery Mode Yellow Lighting
Charging Mode Green Flashing every 2 secondsOverload Red Flashing every 0.5 seconds
Fault Red Lighting
10%Output Voltage Regulation (Battery Mode)
350 x 146 x 160287 x 100 x 142
Less than 40dBANoise Level0-90% relative Humidity, 0C - +40CHumidity
84.25 4.9Dimension (mm) D x W HNet Weight (kgs)
*All specications, designs and contents are subject to change without prior notice.
-
35
Line Interactive UPS
PRO Series
Line Interactive Series 650VA 1200VA
Built-in super smart charger, shorten 50% of charging time Excellent microprocessor control guarantees high reliability Boost and buck AVR for voltage stabilization Auto restart while AC is recovering Simulated sine wave Off-mode charging Cold start function Optional USB/RS-232 communication port and RJ-11/RJ-45 protection Offering LED and LCD panels for selections
PRO Series is a single-phase input / single-phase output line-interactive UPS system. It is able to provide clean electrical power and is ideal for home / small ofceapplications. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage. This prevents under voltage brownouts and over voltage surges. The unit also comes with universal sockets to provide better compatibility with a wider range of devices.
Rear PanelFor 650VA to 1200VA model1. AC Input2. Backup Output3. Bypass Output (without battery back up)4. USB Port (Only available in VU and SVU series)5. RJ11
PC Printer Work-Stations
PRO700V/ VU PRO850VU PRO850SU PRO1200SV/ SVU
12
2
45
12
2 3
4
1
2
2
3
5
1
2
2
4
-
36
Line Interactive UPS
Full Specications
50 or 60Hz (Auto Sensing)25%
220/ 230/ 240VACNominal VoltageVoltage RangeNominal Frequency
Capacity650VA
Watt1200
1 x 12V8.2AH 1 x 12V10AH 2 x 12V8.2AHNumber of BatteryRecharge Time (Typical)
Battery Mode Sounding every 10 secondsLow Battery Sounding every second
Overload Sounding every 0.5 secondsBattery Replacement Alarm Sounding every 2 seconds
Fault Continuously Sounding
INPUT
MODELS PRO700V/ VU850
360 600480
PRO850VU/ SU PRO1200SV/ SVU
OUTPUT
BATTERY
PROTECTION
MANAGEMENT
ENVIRONMENT
PHYSICAL
INDICATION
ALARM
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MACUSB/ RS-232
LED Display
Sounding
Simulated SinewaveTransfer Time (Typical)Frequency
Waveform2 - 8ms 2 - 6ms, 10ms (max)
50Hz or 60Hz 1Hz
Full Protection Short Circuit, Overload, Discharge and Overcharge Protection
4 - 6 hours recover to 90% capacity
AC Mode Green LightingBattery Mode Yellow Lighting
Charging Mode Green Flashing every 2 secondsOverload Red Flashing every 0.5 seconds
Fault Red Lighting
10%Output Voltage Regulation (Battery Mode)
350 x 146 x 160287 x 100 x 142
Less than 40dBANoise Level0-90% relative Humidity, 0C - +40CHumidity
84.25 4.9Dimension (mm) D x W HNet Weight (kgs)
*All specications, designs and contents are subject to change without prior notice.
-
37
PRO-L Series
Line Interactive Series 600VA 2000VA
Excellent microprocessor control guarantees high reliability Boost and buck AVR for voltage stabilization Adjustable battery charging current Auto restart which AC is recovering Off-mode charging Cold start charging Simulated sine wave
PRO-L Series is a single-phase input / single-phase output line-interactive UPS system that provides clean and reliable back-up power for longer periods of time. It is able to provide clean electrical power and is ideal for home / small ofce applications. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage. High voltage batterychargers and battery extension assembly are madeavailable for longer runtime applications. The PRO-L Series with capacities of up to 850VA also comes with universal sockets to provide better compatibility with a wider range of devices.
Rear PanelFor 600VA to 2000VA model1. AC input2. Input protection3. Output outlet4. Battery Connection5. Fan
PC Printer Work-Stations
Line Interactive UPS
PRO1000L/PRO2000L
PRO700L
512
3
4
5
1
2
33
4
-
38
Line Interactive UPS
Battery PackFor 600VA to 2000VA model
Model
Battery Type
Battery Number
Dimension (DxWxH) mm
G6
6 pcs
397 145 220
12 pcs
G12 G18 G60
18 pcs 60 pcs
421 190 318 535 190 318
12V7AH/ 12V9AH/ 12V10AH
830 x 250 x 576
Full Specications
50 or 60Hz (Auto Sensing)25%
220/ 230/ 240VACNominal VoltageVoltage RangeNominal Frequency
Capacity600VA
Watt2000
12VDC 24VDCBattery VoltageBattery CapacityCharging Current (max.)
Battery Mode Sounding every 10 secondsLow Battery Sounding every second
Overload Sounding every 0.5 secondsBattery Replacement Alarm Sounding every 2 seconds
Fault Continuously Sounding
INPUT
MODELS PRO700L1000
360 1200600
PRO1000L PRO2000L
OUTPUT
BATTERY
Dimension (mm) D x W H
PROTECTION
ENVIRONMENT
PHYSICAL
INDICATION
ALARM
LED Display
Sounding
Simulated SinewaveTransfer Time (Typical)Frequency
Waveform
50Hz or 60Hz 1HzTypical 2-6ms, 10ms max.
Full Protection Short Circuit, Overload, Discharge and Overcharge Protection
Depending on the application
AC Mode Green LightingBattery Mode Yellow Lighting
Charging Mode Green Flashing every 2 secondsOverload Red Flashing every 0.5 seconds
Fault Red Lighting
10%Output Voltage Regulation (Battery Mode)
395 x 145 x 220358.5 x 96.8 x 146.5
5A/ 10A/ 15A/ 20A (adjustable)2.5A/ 6A/ 10A (adjustable)
Less than 40dBANoise Level0-90% relative Humidity, 0C - +40CHumidity
9.55.8 9.0Net Weight (kgs)
*All specications, designs and contents are subject to change without prior notice.
-
39
PRO Rack/ Tower Series
Line Interactive Series 800VA 3000VA
Microprocessor-based line interactive design Pure sine wave output online mode and battery mode User-friendly and easy-shift LCD display Rack/Tower design Built-in boost and buck AVR Output power factor 0.8 Hot-swappable battery design Programmable power management outlets Emergency Power Off Function (EPO) Long-run models available Multiple communication available Option for SNMP communication.
PRO Rack / Tower series is a single-phase input / single-phase output UPS that employs a line-interactive technology. This device comes with a practical 2U universal-mount case that provides an option for the user to either install it as a floor-standing tower or in a mounting position using a 19-inch rack mount bracket. With its high density output power factor of 0.8, this device is able to provide outstanding performance and efciency for any home / small ofce applica-tions. A wide input voltage range is supported due to the integrated 3-Step AVR which features 2 boosts and 1 buck to regulate output voltage.
Rear PanelFor 800VA to 3000VA model1. Programmable outlets: Connect to non-critical loads2. Output receptacles: Connect to mission-critical loads3. AC input4. Input circuit breaker5. Network/Fax/Modem surge protection6. Emergency power off function connector (EPO)7. USB communication port8. RS-232 communication port9. SNMP intelligent slot10. Battery Compartment (only available for Standard model)11. Output terminal (IEC320-14)12. Fan13. External battery pack numbers detection port
Line Interactive UPS
PC Printer Work-Stations 19 RackMount
PRT800S
PRT1100S/ PRT1100L/ PRT2000S/ PRT2000L
PRT3000S/ PRT3000L
5 16
7
89 12
13 2
34
5 16
7
89 12
1013 2
34
5 167
891212
10
13 2
113
4
-
40
Line Interactive UPS
Battery PackFor 1.1kVA to 3kVA model
Model
Battery Type
Battery Number
Dimension (DxWxH) mm
G8R G12R G20R
480 x 438 x 88
8 pcs 12 pcs 20 pcs
12V7AH/ 12V9AH/ 12V10AH
580 x 438 x 133600 x 438 x 88
Full Specications
50 or 60Hz162 ~ 290VAC
208/ 220/ 230/ 240VACNominal VoltageVoltage RangeNominal Frequency
Capacity 800 VA/ 640 W 3000 VA/ 2400 W
15% THD 8% THD
Waveform
4.0 A (max.)Depending on the applicationDepending on the application
Charging CurrentCapacityType
AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery
380 x 438 x 88
INPUT
MODELS PRT800S1100 VA/ 880 W
PRT1100S/ L PRT3000S/ L2000 VA/ 1600 W
PRT2000S/ L
OUTPUT
Voltage DistortionLiner LoadNon-Liner Load
EFFICIENCY
MANAGEMENT
ENVIRONMENT
PHYSICAL
INDICATORS
BATTERY
Long-Run Model
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MACUSB/ RS-232
Standard Model
LCD Display
3:1Power FactorFrequency
Current Crest Ratio0.8
50Hz or 60Hz 1Hz
AC Mode Up to 97%
Pure Sinewave
Value regulated Lead Acid battery (Maintenance free batteries)
4 hours recover to 90% capacity 1.0 A (max.)
TypeCapacityRecharge Time (Typical)Charging Current
3%Static Regulation (Battery Mode)
600 x 438 x 88380 x 438 x 88
45dBA @ 1 Meter
0C - +40CNoise LevelAmbient Temperature
0-90% non-condensingOperation Humidity
18480 x 438 x 88
14N/A
10.8Long-Run Model
Dimension (mm) D x W H
Standard ModelDimension (mm) D W H
Net Weight (kgs)
Net Weight (kgs) 12.9 14.23480 x 438 x 88
23.11600 x 438 x 88
32.24
7AH 9AH
*All specications, designs and contents are subject to change without prior notice.
-
41
Inverter UPS
IPS Series
LCD Inverter Series
Simulated sine wave inverter 10 A or 20 A charging current Auto restart while AC is recovering Overload and short circuit protection Generators & Computer-related devices compatible LCD and LED indicators Cold start function
PROLiNK IPS LCD Series is a compact inverter system that delivers high efciency conversion from DC to AC power. This economically ideal system provides clean and stable power for home appliances and electronic devices. With a built-in 20Amp DC charger current, this unit is able to charge a VRLA battery of up to 200Ah. In addition, the PROLiNK IPS LCD series comes with a universal socket outlet that provides the versatility to be utilized in various situations.
Rear PanelFor 1200VA to 5000VA model1. Battery Connector2. Input Protector3. AC Input4. Inverter Output5. Narrow/ Wide Selector (only available for IPS1200 and IPS2400)6. 10Amp/20Amp Charging Current Selector (only available for IPS1200 and IPS2400)
IPS1200/ IP2400
56
1 2
3
IPS3000 IPS5000
1
23 4
12 3 4
4
-
42
Full Specications
*All specications, designs and contents are subject to change without prior notice.
Inverter UPS
170 - 280VAC162 - 290VAC90 - 280VAC
220/ 230/ 240VACNominal Voltage
Voltage Range Narrow RangeWide Range
VAWatt
Capacity5000
10Amp / 20Amp (selectable) 20AmpCharging CurrentDC Voltage
INPUT
MODELS1200
IPS12002400
IPS24003000
4200720 1440 2500
IPS3000 IPS5000
OUTPUT
BATTERY
ENVIRONMENT
PHYSICAL
EFFICIENCY
Alarm
Sounding
INDICATION
LED Display
LCD Display
10%50Hz or 60Hz
Output Voltage Regulation (Battery Mode)Frequency
1HzFrequency Regulation (Battery Mode)
WaveformTransfer Time
Simulated Sinewave Pure Sine Wave10ms Typical, 20ms (max)
24V 48V12VOvercharge Protec 30V 60V15V
AC Mode - GreenBattery Mode - Yellow
Low Battery Yellow flashingShutdown Mode Yellow flashing
Charging Mode - Green flashingCharging Mode - Green flashing
Overload - Red flashing
AC Mode, Inverter Mode,Charger Mode, Load Level, Fault
Input Voltage, Output Voltage,Load level, Battery level, Fault alarm
Overload - Sounding every 0.5 secondsLow Battery - Sounding every 2 seconds
Overcharging Fault Continuously sounding
AC to AC >95%DC to AC >80%
Overload - Sounding every 0.5 secondsLow Battery - Sounding every 2 seconds
High DC Voltage - Continuously soundingFan fault Sounding 2 time every 2 second
N/A
230VACNominal Voltage
407 x 350 x 110268 x 330 x 76293 x 231.5 x 82.5
0~90% Relative Humidity. 0~40CLess than 50dBA Less than 60dBA
HumidityNoise Level
9.02.55 4.92.35Dimension (mm) D x W HNet Weight (kgs)
-
43
Full Specications
PROLiNK PVR
PVR Series
Microprocessor control Accepts wide input voltage range Time delay function eliminates transient that can effect connected equipment Provides stable output voltage Provides under-voltage, over-voltage, over-heat and over current protection High voltage cut off
PROLiNK PVR Series is designed to automatically maintain a constant voltage level to protect sensitive electronics from brownouts, under voltages and over voltages. The PROLiNK PVR takes efciency to a new level with its microprocessor controller tailored to allow extremely fast response for detecting andregulating voltage. Equipped with a time-delay function, the PVR is able to protect connected devices from power-back surges. This high performance AVR comes with the versatility to t all kinds of equipment with its wide input voltage range selection. The PROLiNK PVR provides you with the optimum solution for your everyday needs.
Auto Voltage Regulator
110VAC ~ 270VAC or 140VAC ~ 260VAC (selectable)50 or 60 Hz (Auto Sensing)
Norminal VoltageVoltage RangeNominal Frequency
Capacity VAINPUT
MODELS500
PVR500 D/M1000
PVR1000 D/M2000
92%
PVR2000 D/M3000
PVR3000 D/M
220 VAC
OUTPUT
Humidity
ENVIRONMENT
PHYSICAL
INDICATION
Operating Temperature
LCD/Meter Display
Dimension, D X W X H (mm)Net Weight (kgs)
220 VAC 10%
2.4 6.55 8.563.91
95%
VoltageOutput Voltage Regulation
Normal ModeAVR Mode
10 secondsShort Circuit, Overload and Overvoltage Protection.
Normal indicator, AVR indicator, delay time setting and Fault indicatorInput and Output voltage
196.8 x 110 x 123.5 233.6 x 134 x 181 297.1 x 150 x 199
0C - +40C0-90% relative Humidity (Non-condensing)
Delay TimeFull Protection
PROTECTION
EFFICIENCY
LED Display
D = LCD display, M = Analogue display*All specications, designs and contents are subject to change without prior notice.
-
44
DC UPS
Full Specications
160 - 280VAC50 or 60Hz
220VACNominal VoltageVoltage RangeFrenquency
Capacity
12V9AH x 1Battery TypeCharging VoltageCharging CurrentTypical Recharge Time
INPUT
MODELS50W
PDC50
OUTPUT
BATTERY
AC ModeBattery Mode
EFFICIENCY
ENVIRONMENT
PHYSICAL
PROTECTION
Battery ModeLow BatteryFault
INDICATIONAC Mode
10V ~ 13.7V0ms
>75% at Nominal Voltage (Battery Fully Charged)>95% at Full Load
Output Voltage RegulationTransfer Time
13.7V 0.25V 2.8A or 2.3A at Nominal Voltage without Load
4 ~ 6 hours recover to 90% capacity
Green LightingYellow Lighting
Red LightingYellow Flashing
Full Protection Short Circuit and Overload Protection
12VDCNominal Voltage
228 x 82.5 x 207
0 ~ 90%0C ~ 40C
HumidityTemperature
3Dimension (mm) D x W H @ Vertically StandNet Weight (kgs)
PROLiNK DC UPS
PDC Series - DC UPS
Dual DC Outputs Microprocessor control guarantees high reliability Compact size for standing and mounting flexibility Supports solar powered devices and communication applications Auto restart while AC is recovering Off-mode charging Overload protection and short circuit protection
PROLiNK PDC series is a compact DC UPS system that converts AC to DC power. This device comes with a built-in dynamic voltage regulator that ensures the voltage from the power source is kept within acceptable limits. The PDC Series is ideal for devices such as switches, hubs, routers and modems. With the built-in DC start function, the PDC UPS can be started up with the absence of AC power. The PROLiNK PDC series is denitely your number one choice for back-up power solution.
-
45
Full Specications
PROLiNK DC BACK-UP UNIT
PBU Series
40W DC UPS DC-powered outlets for 11watts energy saving bulb 3 sets DC-powered outlets for energy saving light bulbs Off mode charging Overload protection in battery mode and short circuit protection LED indication 3-step charging design for extended battery life
PROLiNK Back-Up (PBU) unit is a user-friendly lighting power supply unit that is suitable for home/ outdoor settings. This portable-sized unit is compact in size but it comes with a powerful 230VDC output that can be used for powering up energy saving light bulbs of up to 11W. The unit is designed with the flexibility to be powered by regular AC supply or via the supplied battery. The PROLiNK PBU units potential is best realized for users that commonly experience power blackouts.
The unit is also brilliantly designed to allow a range of flexible display methods: vertically or horizontally standing, wall-mounted or as a portable display; as well as a choice to select between a B22 or E27 light bulb terminal. The PROLiNK Back-Up unit is the perfect cost-effective solution for your lighting requirements.
DC UPS
100VAC 300VACVoltageVoltage Range
Rated PowerINPUT
MODELS50VA/40W
PBU5022 / PBU5027
4 hours recover to 90% capacity
230 VAC
OUTPUT
Humidity
OPERATING ENVIRONMENT
PHYSICAL
PROTECTION
Operating Temperature
Dimension, D X W X H (mm)Net Weight (kgs)
230 VDC160-230 VDC 10%
DC Output
0.67
230 VAC12V7Ah x 1
12 VDC
2-pin Sockets
Battery Type and NumberBattery Voltage
Output Voltage (Batt. Mode)Waveform
Output Voltage (AC Mode)
Typical Recharge Time
Battery Mode Yellow LightingAC Mode Green Lighting
Output Short-circuited Red LightingCharging Mode Green Flashing every 3 secondsLow Battery Yellow Flashing every 2 seconds
Overload Red Flashing every 0.5 secondsOvercharge Red Flashing every 5 seconds
Battery weak at start-up Red and Yellow Flashing 3 times and then shut down
Overload Protection and short circuit protection
228 x 82.5 x 207
0C to 40C0-90% relative Humidity (Non-condensing)
LED Display
INDICATORS
BATTERY & CHARGER
Full Protection
Backup Time Table:
PBU5022 = for B22 light bulb terminal.PBU5027 = for E27 light bulb terminal.*All specications, designs and contents are subject to change without prior notice.
11W Safe Energy Light Bulb x 1 no
11W Safe energy light bulb x 2 nos
11W Safe energy light bulb x 3 nos
11W Safe energy light bulb x 4 nos
Up to 6 hours
Up to 2 hours
Up to 3 hours
Up to 1.5 hours
B22 Connector E27 Connector
-
46All specications, designs and contents are subjected to changes without prior notice.The above Battery back-up calculation is based on estimated values and will be subject to change (Variables include; load consumption, sunshine duration and PV panel peak power supply).
Solar
PROLiNK Solar Inverter
Zonne Series
450W Inverter PWM technology solar charger Off mode charging Overload protection and short circuit protection in battery mode Universal socket
PROLiNK Zonne 450 unit is a compact and user-friendly solar power unit that is suitable for use in home like settings. The Zonne series is designed with a built-in charger controller that facilitates proper charging of the battery, enhancing the overall lifespan of the battery.
Also, the PROLiNK Portable Solar unit comes with the flexibility to be powered by regular AC supply, solar PV modules or via the supplied battery. The Zonne unit is capable of supporting up to one block of 100AH battery, giving users ample amount of power supply to operate multiple home appliances.
External Battery
Solar Panel
Utility Supply
Home Appliance
Backup Time Table:Battery Type Effective Sunshine Duration Application / Load Battery back-up
1 block x 12V40AH 5 hours
2 x energy saving light bulb 8 hours per day
1 x energy saving light bulb1 x Fan
6 hours per day
2 x energy saving light bulb1x Fan
4 hours per day
Battery Type Effective Sunshine Duration Application / Load Battery back-up
1 block x 12V65AH 5 hours
2 x energy saving light bulb 10 hours per day
1 x energy saving light bulb1 x Fan
8 hours per day
2 x energy saving light bulb1x Fan
6 hours per day
-
47*All specications, designs and contents are subjected to changes without prior notice.*Above mentioned Back-up timetable is for reference purpose only.
Solar
Full Specications
90 or 280 VAC (INV. Mode)162-290 VAC (UPS Mode)
220/ 230/ 240VAC
450WZonne 450
Voltage
Voltage Range
Rated Power
12 VDC
10Amp
Battery Voltage
Floating VoltageMaximum Charge Current
AC INPUT
MODELS
OUTPUT
BATTERY & CHARGER
PROTECTION
PHYSICAL
INDICATORSLine ModeBattery ModeLow BatteryShutdown ModeCharging Mode at Power OnCharging Mode at Power OffOverloadOverchargingFault
Simulated SinewaveVoltage Regulation (Batt.Mode)Waveform
Full Protection Overload and Short Circuit Protection
13.4VDC 1.5%
Green LightingYellow Lighting
Yellow Flashing every 2 secondsYellow Flashing every 5 secondsGreen Flashing every 2 secondsGreen Flashing every 5 seconds
Red Flashing for 0.5sec. every secondsRed Flashing every 5 seconds
Red lighting
230VAC10%
Output Voltage
293 x 231.5 x 82.52.35
Dimension (mm) D x W HNet Weight (kgs)
SOLAR CHARGER10Amp12VDC
Charging CurrentSystem Voltage
-
48
Full Specications
PROLiNK PORTABLE SOLAR
PPS Series
70W DC UPS DC-powered outlets for 11watts energy saving bulb 3 x 5V USB charger ports for mobile phones PWM technology solar charger Off mode charging Overload protection and short circuit protection in battery mode 12VDC round pin connector output for 12VDC equipment Option for lamp holder with 2m cable Option for 24W Solar PV panel
PROLiNK Portable Solar (PPS) unit is a compact and user-friendly lighting solar power supply unit that is suitable for use in home / outdoor settings. This portable-sized unit is compact in size but it comes with a powerful 230VDC output that can be used for powering up energy saving light bulbs of up to 11W. In addition, there is also a 5VDC USB port for charging your mobile devices and a 12VDC round pin connector for equipment such as DC fans. The unit is designed with the flexibility to be powered by regular AC supply, solar PC modules or via the supplied battery.
PROLiNK Portable Solar unit provides you the option of doubling up your backup duration by adding another block of 7AH battery on top of theexisting supplied battery. The PPS is the perfect device for users living in rural locations where the power supply is often inconsistent and unstable.
Solar
2 AMaximum PV Array Open Circuit VoltageMaximum Solar Charging Current
CapacityPV INPUT
MODELS70W
PPS70
12VDC 2A x 1 pc5VDC 1A x 3 pcs
30 VDC
AC INPUT
Humidity
OPERATING ENVIRONMENT
PHYSICAL
PROTECTION
Operating Temperature
Dimension, D X W X H (mm)Net Weight (kgs)
230 VAC50 Hz or 60 Hz (auto sensing)
3.8
230 VDC160-230 VDC 10%
DC Output
VoltageFrequency Range
2-pin Sockets Output Voltage (Batt. Mode)Waveform
Output Voltage (AC Mode)
DC ConnectorUSB Charger
12V7Ah x 1 (Optional external battery)12 VDC
4 hours recover to 90% capacity
Overload Protection and short circuit protection
229 x 110 x 123.5
0C to 40C0-90% relative Humidity (Non-condensing)
Battery Type and NumberBattery VoltageTypical Recharge Time
BATTERY & CHARGER
OUTPUT
Full Protection
*All specications, designs and contents are subject to change without prior notice.
Solar
Mobile Phone
Utility Supply
12VDC Supply
3 Outlet For Energy Saving Bulb
External Battery
-
49
Full Specications
PROLiNK Solar System
PCC Series
Intelligent Maximum Power Point Tracking technology Built-in DSP controller with high performance Automatic battery voltage detection Multi-functional LCD Reverse polarity protection for solar panel and battery Overcharge and overload protection Suitable for battery types such as sealed lead acid, vented Gel and NiCd Standard RJ45 port or optional RS-485 communication port for remote monitoring
*All specications, designs and contents are subject to change without prior notice.
PCC Series is a Solar Installation System that combines the benets of both the Maximum Power Point Tracking (MPPT) technology and DSP controller system. The MPPT enhances the PCC Series by transferring the most power from its PV solar modules and the DSP controller system provides a high level ofcomputational performance for real-time signal processing in the solar power inverters. This allows your solar panels to operate at their optimum power output voltage, thereby increasing the level of efciency to 97.7% and at the same time lowering power loss.
Users can start generating green energy for their home applications by integrating the PCC Series with solar panels, inverter and external battery packs. Batteries are compatible with up to 4 types; sealed lead acid, vented, gel and NiCad.
Solar
75V 150VDC50V18A 45A
30 ~ 66V @ 24V 60 ~ 132VDC15 ~ 33V @ 12VMPPT Range @ Operating VoltageMaximum PV Array Open Circuit VoltageMaximum Current
Capacity
>110%: Audiable Alarm YesOverload ProtectionOvercharge ProtectionPolarity Reversal Protection @ Solar Cell & Battery
INPUT
MODELS600W
PCC6003000W
PCC3000300W
PCC300
OUTPUT
PROTECTIONS
ENVIRONMENT
PHYSICAL
INDICATIONLCD Panel
LED Display
Sealed Lead Acid, Vented, Gel, MiCd Battery
-
50
Full Specications
PROLiNK Solar System
PSI HybridHYBRID Series
Works as an On-grid inverter during the day Works as an Off-grid inverter during the night or rainy conditions Pure sine wave output Multiple operations: Grid tie, Off grid, and grid-tie with backup Built-in MPPT solar charger LCD display panel for comprehensive information Multiple communication interface Green substitution for generators
PSI Hybrid Series is a hybrid inverter that combines the solar power system, AC utility and battery power source to supply continuous power to your home / ofce applications. This device is most suitable for rural areas where electrical supply is unstable and inconsistent. The PSI Hybrid series comes with a grid-tie operation mode where surplus electricity can be fed back to the main grid, making it an economic and cost-effective power option. If gaining access on the grid is not possible, the PSI Hybrid Series also comes with an off-grid operation mode where power can be stored directly to the back-up battery, making the Hybrid series one of most versatile solar inverters in the market.
Solar
250VDC ~ 450VDC360VDC
13A
500VDCMaximum DC VoltageMPP Voltage RangeDC Nominal VoltageMaximum Input Current
Capacity
47.5 ~ 50.2HzAC Grid Frequency RangeNominal AC Voltage/ Range
Nominal Output CurrentPower Factor
INPUT (DC)
MODELS3000W
HYBRID 3K
GRID/ UTILITY INPUT (AC)
GRID OUTPUT (AC)
ENVIRONMENT
INTERFACE
PHYSICAL
BATTERY & CHARGENominal DC VoltageMaximum Charging Current
BATTERY MODE OUTPUT (AC)Output VoltageOutput FrequencyOutput WaveformEfciency (DC to AC)
20A
208/ 220/ 230/ 240VAC / 184 ~ 265VAC
Maximum Input Current
13A>0.99
208/220/230/240 VAC50Hz
Pure Sinewave92%
48VDC25A
Dimension (mm) D x W H 420 x 415 x 170Net Weight (kgs) 15.5
208/ 220/ 230/ 240VAC / 175 ~ 280 VACNominal AC Voltage/ Range
RS-485/ RS-232
0~90% Relative Humidity (non-condensing)
0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m)-25C to 60C
Humidity
AltitudeOperating Temperature
Optional SNMP Card and Modbus Card availableOptional Zigbee Card and Wireless device available
Communication PortIntelligent SlotWireless Connection
*All specications, designs and contents are subject to change without prior notice.
-
51
Full Specications
PROLiNK Solar System
PSI On-GridAMNETS Series
1.5KW/2KW/3KW/5KW & 3-phase 10KW on-grid PV inverter Advanced DSP control technology delivers accurate data Smart MPPT technology enhances overall efciency Modular design for easy maintenance Industrial-grade components used for robust operation Up to 15 years of data logging Ingress Protection rated 65 (good for any type of environmental conditions) Comprehensive LCD monitor for easy-reading Free monitoring software
PSI On-Grid Series is a grid-connected photovoltaic power system that is designed to operate at its optimum power output voltage even under unfavourable weather conditions. This device uses high quality Amnetz PV inverters to convert DC to AC power at a maximum conversion efciency of up to 96%. On top of that, this user-friendly device is bundled with a monitoring software kit that allows users to observe from agraphical overview of the module voltage/current and temperature.
Solar
500VDC150 ~ 500VDC
370VDC 600VDC360VDC116/ 150VDC125/ 150VDC
11A 10A 16A 17A250/ 250VDC
Maximum DC PowerMaximum DC VoltageMPP Voltage RangeNominal DC VoltageStart-up Voltage/ Initial Feeding VoltageMaximum Input Current/ Per String
CapacityPhase
Maximum Efciency
DC Reverse-Polarity ProtectionGround Fault Monitoring
INPUT (DC)
MODELS1500W
AMNETZ 15002000W
AMNETZ 20003000W
1 Phase-In 1 Phase-Out
>0.99
3 Phase-In 3 Phase-Out
AMNETZ 30005000W
AMNETZ 500010000W
1650W 2200W 3200W 5300W 11000W450VDC 500VDC 500VDC 900VDC
230VAC 230VAC 230VAC 3/ N/ PE, 230/ 400VAC
6.6A 8.7A 21.7A 14.5A
150 ~ 400VDC 200 ~ 450VDC 320 ~ 800VDC
AMNETZ 10K
OUTPUT (AC)
EFFICIENCY
COMPLIANCE
ENVIRONMENT
INTERFACE
PHYSICAL
Intelligent Slot
PROTECTION
AC Short Circuit ProtectionGrid Monitoring
Dimension (mm) D x W HNet Weight (kgs)
230VAC-20% ~ +15%50Hz / 60Hz
13A
Nominal AC VoltageAC Voltage RangeAC Grid FrequencyNominal Output CurrentPower Factor
96.0% 96.5% 98.0%
YesYesYesYes
160 x 270 x 450 182 x 308 x 515 171.2 x 503.5 x 653.3136.5 x 268.5 x 41020 4011.5 15
USB Card/ Optional: SNMP, RS-232, AS-400 and GPRS Cards
Operating TemperatureHumidity
-25 ~ 55C -25 ~ 60C-25 ~ 60C0 ~ 100% Relative Humidity (Non-condesing)
Altitude 0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m)
CE, VDE 0126-1-1, IEC62109, ENEL Guide 2009, RD 1663, G83/ 1-1, AS3100/ AS4777Standard
*All specications, designs and contents are subject to change without prior notice.
-
52
Full Specications
PROLiNK Solar System
PSI Off-GridOFFNETZ Series
DSP plus microprocessor redundant controllers Pure sine wave output Isolation design between inverter and battery LCD Display and records data up to 15 years Provides multiple communication ports for remote monitoring with software Optional Modbus, SNMP, GPRS communication and AS400 dry contact Option: On-Grid
PSI OFFNETZ Series is an off grid PV inverter that is best used in remote locations without utility services. The device is able to supply generous amount of electrical power to the load via PV modules, battery sources and AC powered sources. The OFFNETZ Series is able to fully utilize the energy from the sun to convert stable electrical power to any home / commercial applications. In the event where it is not possible to draw power from PV modules and battery sources, an AC power source can still be supplied by a generator t